Phoenix Contact PLC-RPT- 24UC/21HC Relay component Nominal voltage: 24 V DC/AC Switching current (max.): 10 A 1 change-o

  • Item no.: 2141020
  • Manufacturer no.: 2900293

Efficient connection to the system cabling by means of V8 adapter. All common input voltages from 12 V DC to 230 V AC. Long electrical life through 16 A relay.

This text is machine translated.

  • Item no.: 2141020
  • Manufacturer no.: 2900293

Efficient connection to the system cabling by means of V8 adapter. All common input voltages from 12 V DC to 230 V AC. Long electrical life through 16 A relay.

This text is machine translated.

  • Power loss at rated condition 0.42 W.
  • Maximum switching voltage: 250 V AC/DC (for voltages greater than 250 V (L1, L2, L3) between the same terminals of adjacent modules, the PLC-ATP separator plate must be set. Potential bridging is then performed with FBST 8-PLC...or...FBST 500...)
  • Minimum switching voltage 12 V DC (at 10 mA)
  • Switching current minimum: 10 mA (at 12 V)
  • Inrush current maximum 30 A (300 ms)
  • Switch-off power (resistive load) maximum:
  • 240 W (AT 24 V DC)
  • 58 W (AT 48 V DC)
  • 48 W (AT 60 V DC)
  • 50 W (AT 110 V DC)
  • 80 W (AT 220 V DC)
  • 2500 VA (AT 250 V AC)
  • Switching capacity:
  • 2 A (AT 24 V, DC13)
  • 0.2 A (AT 110 V, DC13)
  • 0.2 A (AT 250 V, DC13)
  • 6 A (AT 24 V, AC15)
  • 6 A (AT 120 V, AC15)
  • 6 A (AT 250 V, AC15)
  • All mounting positions permitted
  • Mounting instructions: Can be aligned without distance
  • Wire stripping length: 8 mm
  • Conductor cross-section rigid: 0.14 mm² ... 2.5 mm²
  • Conductor cross-section flexible: 0.14 mm² ... 2.5 mm²
  • Conductor cross-section AWG: 26 ... 14
  • Dimensioning surge voltage: 6 kV
  • Insulation: Safe isolation, reinforced insulation
  • Over voltage category III
Type PLC-RPT- 24UC/21HC
Connection Push-in connector
Response time 8 ms
Fall time 10 ms
Contact type 1 change-over
Contact material AgNi
Nominal voltage 24 V DC/AC
Switching voltage (max.) 250 V DC/AC
Switching current (max.) 10 A
Durability 3x 10 7 operations
Features + LED , + diode bridge
IP rating
Relay protection type RT II
Max. temperature +60 °C
Min. temperature -40 °C
Length 94 mm
Width 14 mm
Height 80 mm
Dim (L x W x H) 94 x 14 x 80 mm
Content 1 pc(s)
Depth 94 mm
Product type Relay component

Technical data

  • Power loss at rated condition 0.42 W.
  • Maximum switching voltage: 250 V AC/DC (for voltages greater than 250 V (L1, L2, L3) between the same terminals of adjacent modules, the PLC-ATP separator plate must be set. Potential bridging is then performed with FBST 8-PLC...or...FBST 500...)
  • Minimum switching voltage 12 V DC (at 10 mA)
  • Switching current minimum: 10 mA (at 12 V)
  • Inrush current maximum 30 A (300 ms)
  • Switch-off power (resistive load) maximum:
  • 240 W (AT 24 V DC)
  • 58 W (AT 48 V DC)
  • 48 W (AT 60 V DC)
  • 50 W (AT 110 V DC)
  • 80 W (AT 220 V DC)
  • 2500 VA (AT 250 V AC)
  • Switching capacity:
  • 2 A (AT 24 V, DC13)
  • 0.2 A (AT 110 V, DC13)
  • 0.2 A (AT 250 V, DC13)
  • 6 A (AT 24 V, AC15)
  • 6 A (AT 120 V, AC15)
  • 6 A (AT 250 V, AC15)
  • All mounting positions permitted
  • Mounting instructions: Can be aligned without distance
  • Wire stripping length: 8 mm
  • Conductor cross-section rigid: 0.14 mm² ... 2.5 mm²
  • Conductor cross-section flexible: 0.14 mm² ... 2.5 mm²
  • Conductor cross-section AWG: 26 ... 14
  • Dimensioning surge voltage: 6 kV
  • Insulation: Safe isolation, reinforced insulation
  • Over voltage category III
Type PLC-RPT- 24UC/21HC
Connection Push-in connector
Response time 8 ms
Fall time 10 ms
Contact type 1 change-over
Contact material AgNi
Nominal voltage 24 V DC/AC
Switching voltage (max.) 250 V DC/AC
Switching current (max.) 10 A
Durability 3x 10 7 operations