Bender CTAC35 B98110007 LV current transformer Primary current 125 A Secondary current 0.0167 A Line feed-through (H x W

Image similar
Datasheet (PDF)
EAN:
Part number:
Item no:
Fast track dispatch on Wed 28 Oct

5 Piece(s)
Sales and shipping:
Conrad ElectronicTerms & Conditions

Number
Total (€ 129.99 / piece)
€ 129.99
prav.tax.untaxed incl. VAT 
plus € 19.99 
prav.priceAvailability.ecoparticipation.cost ...
prav.priceAvailability.privatecopyingfee.cost ...
without further shipping costs 
Only 5 Piece(s) available
14-day return policy included

Highlights & Details

Measuring current transformer CTAC35

  • Input current (current) 125 A
  • Output current 0.0167 A
  • Line feed-through diameter 35 mm

Technical specifications

  • Rated voltage: 800 V
  • Over voltage category III
  • Rated surge voltage/pollution degree: 8 kV/3
  • Measuring current transformer circuit CTAC…
  • Primary measured differential current 10 A.
  • Secondary measured differential current 0.0167 A.
  • Rated ratio CN: 10/0.0167 A.
  • Rated current: Max. 180 Ω
  • Rated power 0.05 VA
  • Thermal rated continuous differential current Icth: 30 A.
  • Thermal rated short-time current Ith: 60 x Icth = 2.4 kA/1 s.
  • Rated surge current Idyn: 2.5 x Ith = 6.0 kA/40 ms
  • Rated current I
  • CTAC35 at IΔn ≥ 30 mA 80 A.
  • CTAC35 at IΔn ≥ 300 mA 125 A.
  • Connector type MSTB 2.5/2-ST-5.08
  • Phoenix Contact
  • Connection type: Screw terminals
  • Working temperature -25…+70 °C
  • Protection class installation (DIN EN 60529) IP40
  • Protection class terminals (DIN EN 60529) IP20
  • Flammability class UL94 V-0
Product type

LV current transformer

Primary current

125 A

Secondary current

0.0167 A

0.05 VA

Line feed-through diameter

35 mm

Type

CTAC35

Dim

(L x W x H) 61 x 94 x 100 mm

Output current

0.0167 A

Input current

125 A

Line feed-through (W)

35 mm

Line feed-through (H x W)

35 x 35 mm

Line feed-through (H)

35 mm

Reading category

CAT III

Width

94 mm

Height

100 mm

Length

61 mm

Documents & Downloads

Datasheet

Datasheet 2372856 Bender CTAC35 B98110007 LV current transformer Primary current 125 A Secondary current 0.0167 A Line feed-through (H x W

User & Safety Instructions

User & Safety Instructions 2372856 Bender CTAC35 B98110007 LV current transformer Primary current 125 A Secondary current 0.0167 A Line feed-through (H x W

Description

The CTAC series of transducers are highly sensitive transducers that convert AC currents into an evaluable measurement signal in conjunction with RCM or RCMS series differential current monitoring and evaluation devices.

They are also suitable for use in insulation fault search facilities for IT systems (EDS). They are used to record the test current generated by a test current generator PGH or ISOMETER® iso685. The test current is converted into an evaluable measuring signal in conjunction with the EDS series insulation fault detectors.