Highlights & Details
GROUND fault circuit 3PN type B 63A 100mA 10kA
- Nominal voltage=415 V
- Nominal current=63 A
- Switch-off capacity=10 kA
- Number of pins=3
Technical specifications
- Product type
RCCB
- Number of pins
3
- Release characteristics
B/10kA
- Differential current rating
0.1 A
- Nominal current
63 A
- Nominal current - rounded value
63 A
- Dim
(W x H x D) 72 x 91 x 79 mm
- Switch-off capacity
10 kA
- Factory colour
Blue
White
- Content
1 pc(s)
- Insulation class
II
III
- Nominal voltage
415 V
- Width
72 mm
- Height
91 mm
- Depth
79 mm
- Type
B
Compliance & Certifications
Certified by EU Garan
Documents & Downloads
Datasheet
Datasheet 2524983 Chint 782007 NL210 3PN 63A 100mA B 10kA RCCB B/10kA 3-pin 63 A 0.1 A 415 V
Warranty Terms
Warranty Terms 2524983 Chint 782007 NL210 3PN 63A 100mA B 10kA RCCB B/10kA 3-pin 63 A 0.1 A 415 V
Description
FL switches determine fault currents against earth and protect persons & animals against too high contact voltage in direct and indirect contact. They protect equipment against fire hazard due to insulation faults and are used both in building installation and in industry.
Selection
Type classes
AC type: Tripping occurs when the sinusoidal AC fault current increases slowly.
Type A: The tripping takes place at alternating fault current as well as at slowly rising and also at immediate pulsating DC fault current.
Type B: A triggering occurs at sin. AC fault current, with pulsating DC fault current and with smooth DC fault current.
Release currents
10mA – protection for outdoor use
30mA – protection against direct contact
300mA – protection against indirect contact & fire hazard
Trigger times
Without hesitation
Immediate triggering (without time delay).
Short-term delay G
Activation only after min. 10ms
Selective S.
In the case of series connection of Fl's, the downstream Fl should be triggered as a priority.
This text is machine translated.
Selection
Type classes
AC type: Tripping occurs when the sinusoidal AC fault current increases slowly.
Type A: The tripping takes place at alternating fault current as well as at slowly rising and also at immediate pulsating DC fault current.
Type B: A triggering occurs at sin. AC fault current, with pulsating DC fault current and with smooth DC fault current.
Release currents
10mA – protection for outdoor use
30mA – protection against direct contact
300mA – protection against indirect contact & fire hazard
Trigger times
Without hesitation
Immediate triggering (without time delay).
Short-term delay G
Activation only after min. 10ms
Selective S.
In the case of series connection of Fl's, the downstream Fl should be triggered as a priority.
This text is machine translated.
Scope of delivery
- GROUND fault circuit 3PN type B 63A 100mA 10kA