Product type
Network monitor
Operating voltage
230 V
Type
NR12-001-3x230V
Probe inputs
3
Outputs
1
Fast track dispatch on Fri 23 Oct

55 Piece(s)
Sales and shipping:
Conrad ElectronicTerms & Conditions

Number
Total (€ 45.99 / piece)
€ 45.99
prav.tax.untaxed incl. VAT 
plus € 19.99 
prav.priceAvailability.ecoparticipation.cost ...
prav.priceAvailability.privatecopyingfee.cost ...
without further shipping costs 
14-day return policy included

Technical specifications

Type

NR12-001-3x230V

Product type

Network monitor

Probe inputs

3

Outputs

1

Operating voltage

230 V

Dim

(L x W x H) 58 x 18 x 58 mm

Weight

0

Width

18 mm

Height

58 mm

Length

58 mm

Factory colour

Blue

Depth

150 mm

18 mm

58 mm

58 mm

230-230 V

AC

FALSE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

Screw connection

250-250 V

250-250 V

AC

10 A

230-230 V

8 s

0.1 s

180-250 V

0

0

1

UKCA

not relevant

Documents & Downloads

User & Safety Instructions

User & Safety Instructions 2162006 Eltako NR12-001-3x230V 22001330 Network monitor

Conformity certificate

Conformity certificate 2162006 Eltako NR12-001-3x230V 22001330 Network monitor

Description

Line monitoring relay with rotating field monitoring. Stand-by loss only 0.8 Watt. Series installation device for mounting on mounting rail (1TE) For monitoring 230V AC voltage between 1 to 3 external conductors and the neutral conductor and for monitoring the rotating field (clockwise) in the rotary switch positions 2Ph and 3Ph. In the L1/L2/L3 position, only the rotating field is monitored, regardless of the mains voltage. Supply voltage L1-N 180-250V/50Hz. If L1 fails, the relay will drop immediately without any off-delay. With the lower rotary switch on the front, two pick-up or drop-off voltages can be set and the number of monitored external conductors must be specified. U1: 161V drop-off voltage and 185V pick-up voltage. U2: 196V drop-off voltage and 206V pick-up voltage according to VDE 0100, part 718 (formerly VDE 0108, part 1). LED-display for correct applied voltage. If the polarity is incorrect or if the external conductor is missing, the LED flashes quickly. Off-delay RV can be set with the upper rotary switch from 0.1 to 8 seconds. While the RV time is running, the LED flashes slowly. On-delay 0.5s. Maximum device protection 16A.

This text is machine translated.