Technical specifications

  • Product family: TRIO Power
  • Push-in connection
  • Width 88.5 mm
  • Height: 130 mm
  • Depth: 160 mm
  • Colour: green
  • Ambient conditions: Environmental conditions
  • Protection class: IP20
  • Ambient temperature (operation): -25 °C ... 70 °C (> 60 °C DERATING 1.2 %/K)
  • Ambient temperature (storage/transport): -40 °C ... 85 °C
  • Standards/regulations EN 61000-6-4
  • Mounting type: Rail mounting
  • Insulation properties: Insulation properties
  • Overvoltage category: Overvoltage category
  • Pollution level: 2
  • Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6);15 Hz ... 150 Hz, 2.3g, 90 min
  • Stripped length: 8 mm
  • Conductor cross-section flexible min.: 0.2 mm²
  • Conductor cross-section flexible max.: 1.5 mm²
  • Conductor cross-section rigid min.: 0.2 mm²
  • Conductor cross-section rigid max. 1.5 mm²
  • Mounting position: Horizontal mounting rail NS 35, EN 60715
  • Frequency range: 0.15 MHz ... 80 MHz
  • Protection class: I
  • Rated input voltage range: 600 V DC ... 1500 V DC
  • Input voltage range: 600 V DC ... 1500 V DC -15 % ... +10 %
  • Wide-range input: No.
  • Voltage strength max.: ≤ 1800 V DC 1 s
  • Switch-on current impulse integral (I2t): Typ. 0.15 A2S
  • Current consumption: Type 0.35 A (600 V DC);TYPE. 0.145 A (1500 V DC)
  • Selection of suitable fuse for the input protection: 1 A (gPV)
  • Efficiency: Type. 91.5 % (600 V DC);typ. 90.9 % (900 V DC);typ. 89 % (1500 V DC)
  • Rated output voltage 24 V DC ±1 %
  • Setting range of output voltage (USet): 24 V DC ... 28 V DC (> 24 V DC, limited power constant)
  • Nominal output current (IN): 8 A.
  • Short-circuit-proof: Yes
  • Idle: Yes
  • Regenerative resistance ≤ 35 V DC
  • Protection against overvoltage at output (OVP): ≤ 30 V DC
  • < Ripple: 40 mV SS (Ripple);< 50 mV Vss (Noise)
  • Rise time: ≤ 30 ms (UOUT (10 % ... 90 %)
  • Series switch option: No.
  • No-load operation Power Maximum < 9 W
  • Power loss Nominal load maximum: < 24 W
  • Parallel switching capability: Yes, for redundancy and power increase
  • Safety (secondary side): Electronic
  • Input: 3 kV (test efficiency >4 - symmetric);6 kV (test efficiency >4 - asymmetric)
  • Output:1 kV (test efficiency 3 - symmetric);2 kV (test efficiency 3 - asymmetric)
  • Signal:1 kV (test efficiency 3 - symmetric);2 kV (test efficiency 3 - asymmetric)
  • Signalling types: LED; potential-free signal contact
  • Default: Closed
  • Digital 30 V AC 30 V DC 100 mA
  • Number of phases: 1
  • Insulation voltage input/output: 4.2 kV DC (type test);2.6 kV DC (routine test)
  • MTBF (IEC 61709, SN 29500): > 1500000 h (25 °C);> 900000 h (40 °C);> 400000 h (60 °C)
  • Mounting dimensions
  • Right/left (active) mounting distance: 10 mm / 10 mm (≤ 70°C)
  • Top/bottom (active) mounting distance: 50 mm / 50 mm (≤ 70°C)
  • Mounting instructions: Modular: Horizontal 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertical 50 mm
  • Protective coating: No.
  • Flammability class to UL 94 (housing / terminals): V0
  • Case material: metal
  • Design of the hood: Polycarbonate
  • Operating height: ≤ 4000 m (> 2000 m, derating: 10 %/1000 m)
  • Climate class 3K3 (according to EN 60721)
  • Max. ass. Humidity (operating): ≤ 95% (at 25°C, no condensation)
  • Shock: 18 ms, 30 g, per direction of room (according to IEC 60068-2-27)
  • Electromagnetic compatibility: Conformity to EMC directive 2014/30/EU
  • Low Voltage Directive: Conformity to NSR Directive 2014/35/EU
  • Line-guided interference emission: Line-guided interference emission
  • Interference radiation: Interference radiation
  • Discharge of static electricity: Discharge of static electricity
  • Contact discharge 4 kV (test efficiency 2)
  • 8 kV (test efficiency 3)
  • Note: Criterion B
  • Electromagnetic HF-field: Electromagnetic HF-field
  • 10 V/m test field strength (test strength 3)
  • Fast Transients (Burst): Fast Transients (Burst)
  • Surge voltage load (SURGE): Surge current load (SURGE)
  • Conducted interference: Conducted interference
  • Voltage:10 V (testing efficiency 3)
  • Voltage dips: Voltage dips
  • Criteria: Criteria
  • Criterion A: Normal operating behavior within the defined limits.
  • Criterion B: Temporary impairment of the operating behavior, which the device itself corrects.
  • Surrounding temperature (startup type tested): -40 °C
  • National mains voltage typical: 1500 V DC;600 V DC
  • Voltage type of supply voltage: DC
  • Selection of suitable fuse for the input protection: 1500 V DC
  • DC-operation: DC-operation
  • Derating: > 60 °C ... 70 °C (2.5 %/K)
  • Control deviation: < 1 % (load change static 10 % ... 90< %); 3 % (load change dynamic 10 % ... 90< %, 10 Hz); 0.1 % (input voltage variation ±10 %)
  • Power output 192 W
  • One-conductor/flexible clamping point with wire-end sleeve with plastic sleeve min.: 0.2 mm²
  • Single-conductor/flexible clamping point with wire-end sleeve with plastic sleeve max.: 1.5 mm²
  • One-conductor/clamping point flexible with wire-end sleeve without plastic sleeve min.: 0.2 mm²
  • Single-conductor cable/clamping point flexible with wire-end sleeve without plastic sleeve max.: 1.5 mm²
  • Wire cross section AWG min 24
  • Conductor cross-section AWG max. 16
  • Right/left mounting distance: 0 mm / 0 mm (≤ 40°C)
  • Top/bottom mounting clearance: 50 mm / 50 mm (≤ 70°C)
  • Standard - electrical safety: EN 62109-1:2011
  • Standard - safety low voltage IEC 62109-1:2011 (SELV)
  • Standard - safe separation DIN VDE 0100-410
  • UL approvals UL 62109-1:2014
  • Housing design: Aluminium (AlMg3)
  • Emitted interference: Interference
  • IEC 61000-6-2:2005
  • Signal: DC OK: Signal DC OK
  • Continuous load current 100 mA
  • Signal output: LED-status display: Signal output: LED-status display
  • Designation of signaling: DC OK
  • Status indicator: LED "DC OK" green
  • Input/output: Asymmetric
  • Interference suppression voltage according to EN 55011 55011-3-2 (EN 55022) Class A Application area industry
  • Radio interference radiation according to EN 55011: EN 55011 (EN 55022) Class A Industrial area
  • Relay 13/14 signal: Relay 13/14 signal
  • DC OK: UOUT > 0.9 X UN (UN = 24  VDC)
  • INPUT VOLTAGE RANGE DC: 600 V DC ... 1500 V DC -15 % ... +10 %
  • Note on status display: UOUT > 21.5 V: LED on
  • IEC 62109-1: II.
Product type

DC/DC converter

Type

TRIO-PS-2G/1500DC/24DC/8

Min. input voltage

600 V DC

Input voltage (max.)

1500 V DC

Output voltages

24 V DC

Max. output current

8 A

Output current (max.) - rounded

8 A

Connection

Push-in spring-loaded terminal

Operating temperature (min.)

-25 °C

Operating temperature (max.)

70 °C

Dim

(L x W x H) 160 x 88.5 x 130 mm

Height

130 mm

Length

160 mm

Width

88.5 mm

Content

1 pc(s)

Depth

160 mm

IP20

Recess height

130 mm

UKCA

yes

Documents & Downloads

Datasheet

Datasheet 3562907 Phoenix Contact 1075240 DC/DC converter 24 V DC 8 A Content 1 pc(s)

User & Safety Instructions

User & Safety Instructions 3562907 Phoenix Contact 1075240 DC/DC converter 24 V DC 8 A Content 1 pc(s)

Description

Primary switching DC/DC converter TRIO Power with push-in connection for rail mounting, input: 1500 V DC, output: 24 V DC / 8 A

This text is machine translated.

What kind of DC/DC Converters are you looking for?