• All things technology
  • Delivery within Europe
  • Right to Cancel applies
  • Specialist retailer since 1923

Phoenix Contact 1343940 Power supply unit 24 V DC 20 A 541 VA

Image similar
Datasheet (PDF)
EAN:
Part number:
Item no:
Unavailable

Sales and shipping:
Conrad ElectronicTerms & Conditions

Highlights & Details

Power Supply

  • Output 24 V DC / 20 A
  • Power 541 VA
  • Screws, Push-in spring-loaded terminal

Technical specifications

  • Product family: QUINT Power
  • Push-in connection
  • Width 122 mm
  • Height: 130 mm
  • Depth: 73 mm
  • Ambient conditions: Environmental conditions
  • Protection class: IP20
  • Ambient temperature (operation): -25 °C ... 70 °C (> 60 °C DERATING 2.5 %/K)
  • Ambient temperature (storage/transport): -40 °C ... 85 °C
  • Mounting type: Rail mounting
  • Insulation properties: Insulation properties
  • Overvoltage category: Overvoltage category
  • Pollution level: 2
  • Vibration (operation): 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min.  (In accordance with DNV GL Class C)
  • Stripped length: 8 mm
  • Conductor cross-section flexible min.: 0.2 mm²
  • Conductor cross-section flexible max.: 1.5 mm²
  • Conductor cross-section rigid min.: 0.2 mm²
  • Conductor cross-section rigid max. 1 mm²
  • Mounting position: Horizontal mounting rail NS 35, EN 60715
  • Tightening torque min. 0.5 Nm
  • Protection class: I
  • Rated input voltage range: ± 260 V DC ... 300 V DC
  • Input voltage range: ± 260 V DC ... 300 V DC -13 % ... +30 %
  • Switch-on current impulse: Typical 2 A at 25 °C
  • Switch-on current surge integral (I2t) < 0.1 A2S
  • Inrush current limiter 2 A (after 1 ms)
  • Mains failure bridging time: Typ. 33 ms (3x 400 V AC);typ. 33 ms (3x 480 V AC)
  • POWER CONSUMPTION 1.23 A (± 260 V DC);1.06 A (±300 V DC)
  • Nominal power intake 541 VA
  • Switch-on time typical: 300 ms (from SLEEP MODE)
  • Switch-on time < 1 seconds
  • Selection of suitable fuse for the input protection: 1x 6 A (10 x 38 mm, 30 kA L/R = 2 ms)
  • Efficiency: Type. 93.9 % (400 V AC);typ. 93.8 % (480 V AC)
  • Output characteristic: U/I Advanced;Smart HICCUP;FUSE MODE
  • Rated output voltage 24 V DC
  • Setting range of output voltage (USet): 24 V DC ... 29.5 V DC (power constant)
  • Nominal output current (IN): 20 A.
  • Static Boost (ISTAT.Boost): 25 A.
  • Dynamic boost (IDyn.Boost) 30 A (5 s)
  • Selective Fuse Breaking (ISFB) 120 A (15 ms)
  • MAGNETIC FUSE TRIGGERING A1...A16 / B2...B13 / C1...C6 / Z1...Z16
  • Short-circuit-proof: Yes
  • Idle: Yes
  • Regenerative resistance ≤ 35 V DC
  • Protection against overvoltage at output (OVP): ≤ 32 V DC
  • Remaining ripple: < 60 mV SS (at nominal values)
  • Rise time: < 80 ms (Uout = 10 % ... 90 %
  • Series switching capability: Yes
  • No-load power Maximum < 7 W (400 V AC);< 7 W (480 V AC)
  • Load power rating max.: < 32 W (400 V AC);< 33 W (480  V AC)
  • POWER LOSS SLEEP MODE < 5 W (400  VAC);< 5 W (480  VAC)
  • Parallel switching capability: Yes, for redundancy and power increase
  • Input: Input
  • Output: Output
  • Signal
  • Signalling types: LED, potential-free signal contact, Active signal output Out1 (digital, configurable);Active signal output Out2 (digital, analogue, configurable);Remote contact;Signal earth Snd
  • Default: Closed (Uout > 0.9 usset)
  • DIGITAL 24 V DC 1 A;30 V AC/DC 0.5 A
  • Analogue: 4 mA ... 20 mA ±5 % (load ≤400 Ω)
  • Signal earth Sgnd: Reference potential for Out1, Out2 and Rem
  • Number of phases: 3
  • Insulation voltage input/output: 4 kV AC (type test);2.4 kV AC (routine test)
  • Switching frequency: 90.00 kHz ... 110.00 kHz (auxiliary converter stage);56.00 kHz ... 500.00 kHz (main converter stage);25.00 kHz ... 500.00 kHz (PFC level)
  • MTBF (IEC 61709, SN 29500): > 985000 h (25 °C);> 638000 h (40 °C);> 311000 h (60 °C)
  • Service life (electrolytic capacitors): Life expectancy (electrolytic capacitors)
  • Current 20 A
  • Temperature 25 °C.
  • Time 152000 h
  • Additional text 480 V  AC
  • Mounting dimensions
  • Mounting instructions: Modular: PN ≥50 %, horizontal 5 mm, next to active components 15 mm, vertical 50 mm
  • Modular: PN <50%, horizontal 0 mm, vertical top 40 mm, vertical bottom 20 mm
  • Protective coating: Yes
  • Flammability class to UL 94 (housing / terminals): V0
  • Case material: metal
  • Design of the hood: Stainless steel X6Cr17
  • Execution of side parts: Aluminium
  • Operating height: ≤ 5000 m (> 2000 m, observe derating)
  • Climate class 3K3 (according to EN 60721)
  • Max. ass. Humidity (operating): ≤ 100% (at 25°C, no condensation)
  • Shock: 18 ms, 30 g, per direction of room (according to IEC 60068-2-27)
  • EN 61010-1: II (≤ 2000 m)
  • EN 62477-1: III (≤ 2000 m)
  • CSA: CAN/CSA-C22.2 NO. 60950-1-07;CSA-C22.2 NO. 107.1-01
  • SIQ: Type-tested
  • EMC requirements for emission of interference EN 61000-6-3;EN 61000-6-4
  • EMC requirements for immunity EN 61000-6-1;EN 61000-6-2
  • EMC requirements for power station: IEC 61850-3;EN 61000-6-5
  • Surrounding temperature (startup type tested): -40 °C
  • TRACK APPLICATIONS: EN 50121-3-2 ;EN 50121 -4;EN 50121 -5;IEC 62236-3-2 ;IEC 62236-4;IEC 62236-5
  • Control input (configurable) REM: Power output ON/OFF (SLEEP MODE)
  • AC operation: AC operation
  • Grid type: Star network
  • National mains voltage typical: 400 V AC;480 V AC
  • Voltage type of supply voltage: DC
  • Frequency range AC: 50 Hz ... 60 Hz -10 % ... +10 %
  • Frequency range (FN): 50 Hz ... 60 Hz -10 % ... +10 %
  • Protective circuit: Transient overvoltage protection | Varistor, gas deflector
  • Power factor (cos phi) 0.94
  • Selection of suitable fuse for the input protection: ≥ 1000 V DC
  • Leakage current against PE: < 3.5 mA;1.7 mA (550 V AC, 60 Hz)
  • DC-operation: DC-operation
  • Derating: > 60 °C ... 70 °C (2.5 %/K)
  • Control deviation: < 0.5 % (load change static 10 % ... 90 < %); 3 % (load change dynamic 10 % ... 90 < %, (10 Hz)); 0.25 % (input voltage variation ±10 %)
  • POWER OUTPUT 480 W;600 W;720 W.
  • Crest factor: Typ. 1.78 (400 V AC);typ. 2.1 (480 V/ AC)
  • Signal Out 1 (configurable): Signal Out 1 (configurable)
  • Signal Out 2 (configurable): Signal Out 2 (configurable)
  • Signal relay 13/14 (configurable): Signal relay 13/14 (configurable)
  • One-conductor/flexible clamping point with wire-end sleeve with plastic sleeve min.: 0.2 mm²
  • Single-conductor/flexible clamping point with wire-end sleeve with plastic sleeve max.: 0.75 mm²
  • One-conductor/clamping point flexible with wire-end sleeve without plastic sleeve min.: 0.2 mm²
  • Single-conductor cable/clamping point flexible with wire-end sleeve without plastic sleeve max.: 1.5 mm²
  • Wire cross section AWG min 24
  • Conductor cross-section AWG max. 16
  • Tightening torque max. 0.6 Nm
  • Signal output: Signal output
  • Pout: > 100 % (LED is amber, output power > 480 W);> 75 % (LED is green, output power > 360 W);> 50 % (LED is green, output power > 240 W)
  • Uout: > 0.9 x USet (LED lights up green);< 0.9 x USet (LED flashes green)
  • Insulation voltage output/PE: 0.5 kV DC (type test);0.5 kV DC (routine test)
  • Insulation voltage input/PE: 3.5 kV AC (type test);2.4 kV AC (routine test)
  • Environmental Protection Directive: RoHS Directive 2011/65/EU;WEEE;Reach
  • Installation distance right / left 5 mm / 5 mm
  • Installation distance above/below 50 mm / 50 mm
  • Standard - limitation of mains harmonic currents EN 61000-3-2
  • Standard - Electrical safety: IEC 61010-2-201 (SELV)
  • Standard - safety extra-low voltage: IEC 61010-1 (SELV);IEC 61010-2-201 (PELV)
  • Standard - Safe isolation: IEC 61558-2-16;IEC 61010-2-201
  • Standard - safety for measurement, control, regulation and laboratory devices: IEC 61010-1
  • Standard - transformer safety EN 61558-2-16
  • Approval - requirement of the semiconductor industry with regard to mains voltage drops: SEMI F47-0706, EN 61000-4-11
  • UL approvals UL listed UL 508;UL/C-UL recognized UL 60950-1;UL ANSI/ISA-12.12.01 class I, division 2, groups a, B, C, D (Hazardous Location)
  • Output: 686 VA (400 V, UOUT = 24 V, IOUT = static. Boost);698 VA (480 V, UOUT = 24 V, IOUT = stat. Boost)
  • Alternative assembly: Alternative assembly
  • HART FSK Physical Layer Test Specification Compliance: Output voltage Uout compliant
  • DNV GL, PRS, BV, LR, ABS WERE APPROVED FOR SHIPBUILDING
Product type

Power supply unit

Input voltage (max.)

500 V AC

300 V DC

Max. output current

20 A

Output current (max.) - rounded

20 A

Min. input voltage

400 V AC

260 V DC

Dim

(L x W x H) 125 x 70 x 130 mm

Output voltage (max.)

24 V DC

Connection

Screws

Push-in spring-loaded terminal

541 VA

IP20

Protection class

I

Operating temperature (max.)

70 °C

Max. operating temperature (derating)

70 °C

Min. operating temperature (derating)

60 °C

Operating temperature (min.)

-25 °C

Operating temperature

-25 °C - 70 °C

Width

70 mm

Height

130 mm

Length

125 mm

Type

QUINT4-PS/3AC/24DC/20/CO

Depth

125 mm

Recess height

130 mm

UKCA

yes

Documents & Downloads

Datasheet

Datasheet 3587976 Phoenix Contact 1343940 Power supply unit 24 V DC 20 A 541 VA

User & Safety Instructions

User & Safety Instructions 3587976 Phoenix Contact 1343940 Power supply unit 24 V DC 20 A 541 VA

Description

Primary clocked power supply QUINT Power, screw terminal, mounting rail, input 3-phase, output 24 V DC / 20 A

This text is machine translated.