User & Safety Instructions 2577408 Sievert 721512 Heatshrink burner set
Description
The Promatic heat shrink burner set in the Powercase has been specially designed for the requirements of cable and pipe construction. The set contains various shrink burners with which shrink tubes can be processed in all common sizes. The safety regulator also included in the set ensures work under ground level and fulfills the requirements of the professional association.
This text is machine translated.
Scope of delivery
PROMATIC UniversalHand grip 336611PROMATIC Shrink burner 28mmPROMATIC Shrink burner 38mmPROMATIC Shrink burner 50mmPROMATIC Standard Burner 19mmPropane hose 4x4mm, length: 4 metersSafety regulator with leak-gas testing device2x open end wrench 701623Powercase carrying case
Hints
When working with propane, it is important to remember that propane is heavier than air! Therefore, there is a particular risk of explosion in rooms that cannot be ventilated (e.g. cellars, pits, tanks), as propane gas collects in such rooms on the ground and can thus form an ignitable gas/air mixture. In accordance with the UVV for the use of LPG BGV D34 (formerly VBG 21, the use of fuel consumption devices operated with LPG must therefore be carried out under the same leakage safety conditions.
The Promatic heat shrink burner set in the Powercase has been specially designed for the requirements of cable and pipe construction. The set contains various shrink burners with which shrink tubes can be processed in all common sizes. The safety regulator also included in the set ensures work under ground level and fulfills the requirements of the professional association.
This text is machine translated.
Scope of delivery
PROMATIC UniversalHand grip 336611PROMATIC Shrink burner 28mmPROMATIC Shrink burner 38mmPROMATIC Shrink burner 50mmPROMATIC Standard Burner 19mmPropane hose 4x4mm, length: 4 metersSafety regulator with leak-gas testing device2x open end wrench 701623Powercase carrying case
Hints
When working with propane, it is important to remember that propane is heavier than air! Therefore, there is a particular risk of explosion in rooms that cannot be ventilated (e.g. cellars, pits, tanks), as propane gas collects in such rooms on the ground and can thus form an ignitable gas/air mixture. In accordance with the UVV for the use of LPG BGV D34 (formerly VBG 21, the use of fuel consumption devices operated with LPG must therefore be carried out under the same leakage safety conditions.
What kind of Gas Soldering Accessories are you looking for?