• All things technology
  • Delivery within Europe
  • Right to Cancel applies
  • Specialist retailer since 1923

Ziehl MU2000K T236056 Transducer

EAN:
Part number:
Item no:
1/2
Product type
Transducer
Type
MU2000K
Probe inputs
Messeingang Spannung: AC/DC 0-30/150/300/600 V. 80-120 V. Ri = 500 kΩ. max. 600 V;max. 300 V gegen GND Genauigkeit: DC ≤ 0.1% AC ≤ 0.5% (50/60 Hz) vom Endwert;Temperaturdrift < 0.02 %K Messeingang Strom: AC/DC 1A. 5A. max. 7.5A/4s. 25A/1s. 30 mΩ Genauigkeit: DC ≤ 0.1% AC ≤ 0.5% (50/60 Hz) vom Endwert;Temperaturdrift < 0.02 %K
Operating voltage
24 VDC<br>48 V/DC<br>110 V/AC<br>230 V/AC<br>24 V/AC<br>48 V/AC<br>110 V DC<br>230 V DC
Datasheet (PDF)
Fast track dispatch on Fri 23 Oct

11 Piece(s)
Sales and shipping:
Conrad ElectronicTerms & Conditions

Number
Total (€ 214.99 / piece)
€ 214.99
prav.tax.untaxed incl. VAT 
plus € 19.99 
prav.priceAvailability.ecoparticipation.cost ...
prav.priceAvailability.privatecopyingfee.cost ...
without further shipping costs 
14-day return policy included

Highlights & Details

Universal transducer type MU 2000 K AC and DC

  • AC and DC measurement without having to change possible
  • Zero point and full scale for further measuring ranges can be scaled in any way by the user.
  • Electrical isolation between input, output and control voltage

Technical specifications

  • Control voltage Us: 24 V AC/DC-240V, 0/50/60 Hz< 3W< 8VA; 20.4 - 297V, AC 20 - 264 V
  • Measuring input voltage: AC/DC 0-30/150/300/600 V, 80-120 V, Ri = 500 kΩ, max. 600 V; max. 300 V against GND
  • Accuracy: DC ≤ 0.1% AC ≤ 0.5% (50/60 Hz) of the final value; temperature drift< 0.02% K
  • Measuring input current: AC/DC 1 A, 5 A, max. 7.5A / 4s 25 A/1 s, 30 mΩ
  • Accuracy: DC ≤ 0.1% AC ≤ 0.5% (50/60 Hz) of the final value; temperature drift< 0.02% K.
Type

MU2000K

Product type

Transducer

Probe inputs

Messeingang Spannung: AC/DC 0-30/150/300/600 V. 80-120 V. Ri = 500 kΩ. max. 600 V;max. 300 V gegen GND Genauigkeit: DC ≤ 0.1% AC ≤ 0.5% (50/60 Hz) vom Endwert;Temperaturdrift < 0.02 %K Messeingang Strom: AC/DC 1A. 5A. max. 7.5A/4s. 25A/1s. 30 mΩ Genauigkeit: DC ≤ 0.1% AC ≤ 0.5% (50/60 Hz) vom Endwert;Temperaturdrift < 0.02 %K

Operating voltage

24 VDC
48 V/DC
110 V/AC
230 V/AC
24 V/AC
48 V/AC
110 V DC
230 V DC

Documents & Downloads

Datasheet

Datasheet 1462373 Ziehl MU2000K T236056 Transducer

User & Safety Instructions

User & Safety Instructions 1462373 Ziehl MU2000K T236056 Transducer

User & Safety Instructions 1462373 Ziehl MU2000K T236056 Transducer

Description

Measuring transducer MU 2000 K can be used as input signals ac and dc voltages up to 600 V, as well as direct and alternating currents of 0 … 1/5 A measure. There are pre-programd measurement ranges are available. Further measuring range can easily be scaled.

The output signals 0/2-10V and 0/4-20mA are galvanically isolated from the measurement input and control voltage. With its universal power supply AC/DC 24-240 V, the transducer on all standard supply voltages can be operated.

The MU 2000 K is suitable for example for the measurement of voltages and charging currents of batteries. As a measuring transducer for AC signals, it can be voltages and currents in self-generation plants.

This text is machine translated.

Hints

Zero point and full scale for further measuring ranges can be scaled in any way by the user.

More interesting products

(*All information is plus legal VAT)