Monitoring relay 1 change-over ENTES GKRC-20F 1 pc(s)

Product type
Monitoring relay
Functions
Voltage
Contact type
1 change-over
Switching current (max.)
8 A
Type
GKRC-20F
Datasheet (PDF)
EAN:
Part number:
Item no:
Unavailable

Sales and shipping:
Conrad ElectronicTerms & Conditions

Total (€ 75.99 / piece)
€ 75.99
prav.tax.untaxed incl. VAT 
plus € 19.99 
prav.priceAvailability.ecoparticipation.cost ...
prav.priceAvailability.privatecopyingfee.cost ...
without further shipping costs 
14-day return policy included

Highlights & Details

GKRC-20F voltage monitoring relay

  • 230 V/AC, 400 V/AC ± 30% operating voltage
  • Undervoltage setting range 300 to 400V/AC
  • Overvoltage setting range 400 to 500 V/AC
  • Overvoltage protection
  • Undervoltage protection
  • Monitoring between two phase-failure protection limits
  • Phase sequence protection
  • Switch-off delay
  • 1 8A relay output

Technical specifications

  • Undervoltage setting range: 300 – 400 V/AC
  • Overvoltage setting range: 400 – 500 V/AC
  • Immediate switch period: 500 ms
  • Mains power supply: 1-phase, 2-conductors or 3-phase, 4-conductors
Product type

Monitoring relay

Type

GKRC-20F

Functions

Voltage

Operating voltage

230 V AC

400 V AC

Operating voltage
Adjustment range (amperage)
Contact type

1 change-over

Switching current (max.)

8 A

Min. temperature

-5 °C

Max. temperature

+55 °C

Width

35 mm

Height

90 mm

Depth

58 mm

Dim

(W x H x D) 35 x 90 x 58 mm

Content

1 pc(s)

Type

Voltage monitoring relay

Hysteresis

3 %

Type

GKRC-20F

Temperature range

-5 – +55 °C °C

Reading category

3

Operating voltage

230 V/AC/ (±30 %) 400 V/AC

Documents & Downloads

Datasheet

Datasheet 507142 Monitoring relay 1 change-over ENTES GKRC-20F 1 pc(s)

User & Safety Instructions

User & Safety Instructions 507142 Monitoring relay 1 change-over ENTES GKRC-20F 1 pc(s)

Description

Voltage monitoring relay for the protection of one-phase and three-phase networks against power fluctuations and incorrect phase sequence. Faulty alarm responses due to voltage spikes are prevented by a switching delay (0.1 – 10 s). The relay switches immediately if the voltage of a phase exceeds or falls below the nominal voltage by more than 50%.

Features

  • Overvoltage protection
  • Undervoltage protection
  • Monitoring between two limits
  • Phase-failure protection
  • Phase sequence protection
  • Switch-on delay