NET-DEV-REL16_5A
- 16 relay outputs
- AC SWITCHING VOLTAGE (36V / 5A / 78W)
- DC SWITCHING VOLTAGE (30V / 5A / 60W)
- Time function
- Timeout-output protection can be configured via software
- LED status display for each output channel
- Galvanically isolated via relay
- Suitable for DIN rail mounting
Technical specifications
- Product type
GPO module
- Interfaces
Serial
Ethernet
CAN
USB
- Type
NET-DEV-REL16_5A
- Operating voltage
7 V
24 V
- Operating voltage
V/DC
- Height
114.5 mm
- Length
99 mm
- Width
22.5 mm
- Max. modules
64
- No. of digital inputs
0
- No. of digital inputs
0
- No. of digital outputs
16
- No. of relay outputs
16
- Dim
(L x W x H) 99 x 22.5 x 114.5 mm
- Control LEDs
Yes
- Manufacturer part #
NET-DEV-REL16_5A
- Fitting type (details)
DIN rail (TS 35)
Documents & Downloads
User & Safety Instructions
User & Safety Instructions 2149457 Deditec NET-DEV-REL16_5A NET-DEV-REL16_5A GPO module Serial, Ethernet, CAN, USB No. of digital outputs: 16 No. of digita
Description
The basis of a NET module is a NET CPU BASE with Ethernet/USB interface or a NET CPU-PRO-CS with Ethernet/USB/CAN/serial interface.
Up to 64 different NET-DEV-I/O modules can be combined and connected to these NET-CPU base modules in any way.
Analogue and digital modules can be combined.
Depending on the application, digital and analogue modules can be combined. Module combinations with relays, power relays and A/D inputs as well as temperature recording are therefore no problem. The complete module is mounted on the DIN rail.
Service-friendly change of a single module is possible
Even during operation, individual modules can be replaced or changed. This allows a service-friendly upgrade or the replacement of modules. The next time the entire module is restarted, the NET-CPU interface first scans all NET-DEV I/O modules and thus records the overall module configuration.
This text is machine translated.
Up to 64 different NET-DEV-I/O modules can be combined and connected to these NET-CPU base modules in any way.
Analogue and digital modules can be combined.
Depending on the application, digital and analogue modules can be combined. Module combinations with relays, power relays and A/D inputs as well as temperature recording are therefore no problem. The complete module is mounted on the DIN rail.
Service-friendly change of a single module is possible
Even during operation, individual modules can be replaced or changed. This allows a service-friendly upgrade or the replacement of modules. The next time the entire module is restarted, the NET-CPU interface first scans all NET-DEV I/O modules and thus records the overall module configuration.
This text is machine translated.
Scope of delivery
- Connectors
- Voltage plug
- Actuator tool
- DEDITEC installation CD
- Flyers