Product type
Power feed
Cable type
NHXMH-J
No. of leads
3 x
Cross section (each core)
2.50 mm²
No. of leads (part 2)
3 x
EAN:
Part number:
Item no:
Unavailable

Sales and shipping:
Conrad ElectronicTerms & Conditions

Technical specifications

  • Conductor material: Copper
  • Conductor class: Single-wire
  • Specification of wire insulation: Polyethylene (PE)
  • Wire identification: Colour
  • With ground wire: Yes
  • Max. Load Conductor temperature 70 °C
  • Side wire: No.
  • Protective cover: Without
  • Reinforcement/armoring: Without
  • Fire classification to EN 13501-6: Cca
Product type

Power feed

Cable type

NHXMH-J

No. of leads

3 x

Cross section (each core)

2.50 mm²

No. of leads (part 2)

3 x

Cross section (each core) (part 2)

2.50 mm²

Cross section

3 x 2.50 mm² + 3 x 2.50 mm²

Cable features

Flat

Flexible

Outside Ø

10.40 mm

Factory colour

Grey

Content

100 m

Nominal voltage

500 V

Nominal voltage U0

300 V

Packaged

Yes

Sold per metre

No

Halogen-free

Yes

Manufacturer part #

VER NHXMH-J 3x 2,5 Cca R.100

Insulation material

Polyethylene (PE)

Min. temperature range (flexible installation)

-5 °C

Max. temperature range (flexible installation)

50 °C

Min. temperature range (fixed installation)

-30 °C

Max. temperature range (fixed installation)

70 °C

Max. length sold by the metre

100 m

Type

VER NHXMH-J 3x 2,5 Cca R.100

Shielded

No

Documents & Downloads

User & Safety Instructions

User & Safety Instructions 3336368 VER NHXMH-J 3x 2,5 Cca R.100 Power feed NHXMH-J 3 x 2.50 mm² Grey 100 m

Description

Complies with VDE 0250. Halogen-free plastic sheathed cable with improved behavior in the event of fire according to DIN 0472 part 813. Low heat conduction according to DIN VDE 0472 part 804/test type C. Minimal smoke development according to DIN VDE 0472 part 816. They are used where a high concentration of property value must prevent damage to people and materials in the event of a fire, e.g. in industrial plants, municipal facilities, hotels, airports, etc. subway, train stations, hospitals, department stores, banks, Schools, theaters, cinemas, high-rise buildings, control centers, etc. Suitable for installation in dry, damp or wet rooms, for laying over, on, in and under plaster as well as in masonry and concrete, but not for direct embedding in shaken, vibrated or rammed concrete. They are also suitable for outdoor use as long as they are protected from direct sunlight. Wire color coding according to VDE 0293. Max. operating temperature: 70 °C

This text is machine translated.

Hints

Made in Europe

Accessories

(*All information is plus legal VAT)