Number
Total (€ 25.99 / piece)
€ 25.99
incl. VAT
14-day return policy included
Highlights & Details
CAN terminating resistance / connection plug (Sub-D9, socket)
- High quality and extremely reliable
- Consistent termination of CAN according to ISO 11898-2
- Suitable for use in CAN and CAN FD buses
- Simple use between existing cable connections
Technical specifications
- 120 ohm terminating resistor between pin 2 (CAN-L) and pin 7 (CAN-H)
- 9-pin D-Sub plug to 9-pin D-Sub socket, gender changer design
- Pin assignment 1 to 1.
- Product type
Terminator
- Interfaces
CAN bus
D-SUB9
- Type
CAN/CAN FD Abschlussadapter
- Max. operating temperature
+105 °C
- Min. operating temperature
-55 °C
- Operating temperature
-55 up to +105 °C
- No. of inputs
1 x
- No. of outputs
1 x
- Manufacturer part #
1.04.0075.03000
- UKCA
not relevant
Documents & Downloads
Datasheet
Datasheet 1386482 Ixxat 1.04.0075.03000 CAN/CAN FD Abschlussadapter Terminator CAN bus, D-SUB9 No. of inputs: 1 x No. of outputs: 1 x 1 pc
User & Safety Instructions
User & Safety Instructions 1386482 Ixxat 1.04.0075.03000 CAN/CAN FD Abschlussadapter Terminator CAN bus, D-SUB9 No. of inputs: 1 x No. of outputs: 1 x 1 pc
Description
CAN/CAN FD terminating resistor 120 Ohm / D-Sub connector plug for CAN or CAN FD (plug on socket)
This adapter allows quick and easy termination of any HighSpeedCAN or CANFDproduct. The connector is used when a CAN node needs to be completed without internal termination or when no CAN node is connected at the end of the CAN bus.
According to ISO 11898-2, high-speed CAN buses/systems must be terminated with resistors at their ends.
The Ixxat D-sub termination adapter has a 9-pin D-sub plug on one end and a 9-pin D sub-socket on the other end and can also be used for CAN FDBusses.
This text is machine translated.
This adapter allows quick and easy termination of any HighSpeedCAN or CANFDproduct. The connector is used when a CAN node needs to be completed without internal termination or when no CAN node is connected at the end of the CAN bus.
According to ISO 11898-2, high-speed CAN buses/systems must be terminated with resistors at their ends.
The Ixxat D-sub termination adapter has a 9-pin D-sub plug on one end and a 9-pin D sub-socket on the other end and can also be used for CAN FDBusses.
This text is machine translated.