• All things technology
  • Delivery within Europe
  • Right to Cancel applies
  • Specialist retailer since 1923
Start

Cable FLK 50/EZ-DR/ 750/KONFEK Phoenix Contact Content: 1 pc(s)

Image similar
Product type
Cable
Cable length
7.5 m
Connection
IDC-FLK power strip
Total no. of pins
50
Manufacturer part #
2289638
Datasheet (PDF)
EAN:
Part number:
Item no:
Unavailable

Sales and shipping:
Conrad ElectronicTerms & Conditions

Technical specifications

  • Number of pins: 50
  • Connection type: IDC/FLK power strip
  • Ambient conditions: Environmental conditions
  • IP00 protection
  • Ambient temperature (storage/transport): -40 °C ... 80 °C
  • Altitude: ≤ 2000 m.
  • Note on operation: For the intended use, the requirements of the installation guideline (see downloads) must be observed. In the case of applications or use with third-party products, the requirements, safety and warning notices of the respective third-party manufacturer must also be met.
  • Cable outside diameter 10.30 mm ±0.4 mm
  • Lead wire spacing 2.54 mm
  • Connection according to standard IEC 60603-13 (in accordance with)
  • Outer sheath, material: Semi-rigid PVC
  • Material conductor: Tin-plated Cu-strand
  • Cable length 7.5 m
  • Cable cross-section: 50 x 0.14 mm²
  • Wire resistance: ≤ 145 Ω/km (20 °C)
  • Outer sheath, color: Grey
  • Insulation resistance: ≥ 20 MΩ*km (20 °C)
  • Protection type (installation location): ≥ IP54 (installation location)
  • UL AWM style 2464/1061
  • Shielded: No.
  • Cable type 50x0.14 [PVC]
  • Conductor construction signal line: 7x 0.16 mm
  • AWG signal cable 26
  • Wire diameter including insulation: 1 mm ±0.03 mm
  • Minimum bend radius, 86 mm fixed installation
  • Minimum bend radius, movable 161 mm
  • Dynamic load carrying capacity (bending): Maximum bending cycles: 5000 (at radius ≥ 15x external diameter)
  • Flame retardant according to IEC 60332-1-2 (raw cable);VDE 0842, part 332-1-2 (raw cable) ;IEC 60332-3-22 (raw cable);UL VW-1;CSA FT-1
  • Oil resistance: Against occasional splashes (raw cable)
  • Number of connections: 1
  • Rating type 100 % ED
  • Mating cycles > 50
  • Track 1: Track 1
  • Track 2: Track 2
  • Halogen-free: No.
  • Ambient temperature (operation) (fixed installation): -40 °C ... 70 °C (fixed installation)
  • Ambient temperature (operation) (moving laying): -10 °C ... 70 °C (moving laying)
  • Conductor type: Assembled round cable
  • SUITABLE I/O-CARD TC-IDK 161;TC-IDX 161;TC-IDJ 161;TC-IDD 321;TC-ODD 321;TC-IAH 161
  • OPERATING VOLTAGE (AC) ≤ 30 V AC
  • OPERATING VOLTAGE (DC): ≤ 60 V DC
  • Supported control: Siemens S7-1500: Supported control: Siemens S7-1500
  • Supported control: Siemens S7-300 / ET 200 M: Supported control: Siemens S7-300 / ET 200 M
  • Supported control: Siemens S7-400: Supported control: Siemens S7-400
  • Supported control: HONEYWELL Experion PKS C200: Supported controller: HONEYWELL Experion PKS C200
  • Supported control: ALL-BRADLEY ControlLogix: Supported control: ALL-BRADLEY ControlLogix
  • Supported control: Schneider Electric Modicon TSX Quantum: Supported control: Schneider Electric Modicon TSX Quantum
  • Colour code: Single core: Colour code: Single core
  • WHITE IDC/FLK50 (13 16 17 19) = IDC/FLK50 (13 15 16 18 19);IDC/FLK50 (11 14 15 17 18) = IDC/FLK50 (11);IDC/FLK50 (12) = IDC/FLK50 (12);IDC/FLK50 (14) = IDC/FLK50 (10) = IDC/FLK50 = IDC/FLK50 (10) = IDC/FLK50
  • BROWN IDC/FLK50 (2) = IDC/FLK50 (2)
  • GREEN IDC/FLK50 (6) = IDC/FLK50 (6)
  • YELLOW: IDC/FLK50 (5) = IDC/FLK50 (5)
  • GRAY:IDC/FLK50 (9) = IDC/FLK50 (9)
  • BLUE IDC/FLK50 (7) = IDC/FLK50 (7)
  • RED IDC/FLK50 (3) = IDC/FLK50 (3)
  • BLACK IDC/FLK50 (1) = IDC/FLK50 (1)
  • VIOLET:IDC/FLK50 (8) = IDC/FLK50 (8)
  • BROWN-BLACK: IDC/FLK50 (23 26 27) = IDC/FLK50 (23 25 26 28);IDC/FLK50 (21 24 25 27 28) = IDC/FLK50 (21);IDC/FLK50 (22) = IDC/FLK50 (22);IDC/FLK50 (24) = IDC/FLK50 (20) = IDC/FLK50 = IDC/FLK50 (20) (IDC/FLK50) = IDC/FLK50
  • GREEN-BLACK: IDC/FLK50 (32 33 35 36) = IDC/FLK50 (32 34 35);IDC/FLK50 (30 33 34 36) = IDC/FLK50 (30);IDC/FLK50 (31) = IDC/FLK50 (31);IDC/FLK50 (29) = IDC/FLK50 (29) = IDC/FLK50
  • YELLOW-BLACK: IDC/FLK50 (40 41 43 44) = IDC/FLK50 (40 42 43);IDC/FLK50 (38 41 42 44) = IDC/FLK50 (38);IDC/FLK50 (39) = IDC/FLK50 (39);IDC/FLK50 (37) = IDC/FLK50 (37) = IDC/FLK50 = IDC/FLK50
  • GRAY-BLACK: IDC/FLK50 (45 49) = IDC/FLK50 (45 50);IDC/FLK50 (46 49 50) = IDC/FLK50 (46);IDC/FLK50 (47) = IDC/FLK50 (47);IDC/FLK50 (48) = IDC/FLK50 (48)
  • ORANGE: IDC/FLK50 (4) = IDC/FLK50 (4)
  • Cable design: Cable for one module
  • Current (per path, 50 °C): ≤ 1 A (in the unrolled state, see derating)
  • Current (per path, 70 °C): ≤ 0.6 A (in the unrolled state, see derating)
  • 50X0.14 [ PVC]: 50X0.14]
Product type

Cable

Cable length

7.5 m

Connection

IDC-FLK power strip

Total no. of pins

50

Manufacturer part #

2289638

Content

1 pc(s)

Material

PVC

Number of pins

50

Type

FLK 50/EZ-DR/ 750/KONFEK

Length

7.5 m

UKCA

not relevant

Documents & Downloads

Datasheet

Datasheet 3578878 Cable FLK 50/EZ-DR/ 750/KONFEK Phoenix Contact Content: 1 pc(s)

User & Safety Instructions

User & Safety Instructions 3578878 Cable FLK 50/EZ-DR/ 750/KONFEK Phoenix Contact Content: 1 pc(s)

Description

Pre-fabricated round cable; connector 1: IDC/FLK female header (1x 50-pin); connector 2: IDC/FLK female header (1x 50-pin); cable length: 7.5 m.

This text is machine translated.