Technical specifications

  • Axioline F product family
  • Modular design: Block modules
  • Push-in connection
  • Conductor cross-section flexible: 0.2 mm² ... 1.5 mm².
  • Conductor cross-section rigid: 0.2 mm² ... 1.5 mm².
  • Wire cross-section AWG: 24 ... 16
  • Width 53.6 mm
  • Height: 126.1 mm
  • Depth: 54 mm
  • Ambient conditions: Environmental conditions
  • Protection class: IP20
  • Ambient temperature (operation): -25 °C ... 60 °C (standard, applications with UL approval, use in hazardous area of zone 2);-40 °C ... 70 °C (Extended, see chapter "Successfully tested: Use under extreme environmental conditions" in data sheet.)
  • Ambient temperature (storage/transport): -40 °C ... 85 °C
  • Mounting type: Rail mounting
  • Insulation properties: Insulation properties
  • OVERVOLTAGE CATEGORY II (IEC 60664-1, EN 60664-1)
  • Pollution level 2 (IEC 60664-1, EN 60664-1)
  • Permissible air humidity (operation): 5 % ... 95% (no condensation)
  • Name of connection: Axioline F-plug
  • Stripped length: 8 mm
  • Installation position: Any (no temperature derating | parameterize the installation position via object 0080hex ParTable!)
  • ATEX
  • IECEx: IECEx
  • Transmission speed 100 MBit/s
  • Identification: Class I, zone 2, AEx ec IIC T4;class I, division 2, groups A, B, C, D, T4;ex ec IIC T4 GC X
  • UL, USA / Canada: UL, USA / Canada
  • Maximum power loss at rated conditions 2.6 W.
  • Testing period: 21 days
  • PROTECTION CLASS III (IEC 61140, EN 61140, VDE 0140-1)
  • Number of interfaces: 2
  • Air pressure (operation): 70 kPa ... 106 kPa (up to 3000 m üNN)
  • Delivery scope: Inclusive of bus base module and Axioline F-plugs
  • Supply voltage range: 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Certificate: , 2021122309114456
  • Connection technology: Connection technology
  • Permissible humidity (storage/transport): 5 % ... 95% (no condensation)
  • Note for application: Only for industrial use
  • Current consumption: Max. 70 mA;type. 45.3 mA
  • Wire connection: Conductor connection
  • Temperature 25 °C ±1 K
  • Protection circuit: Overvoltage protection | electronic (35 V, 0.5 s);reverse polarity protection | reverse polarity protection diode;transient protection | suppressor diode
  • UKEX
  • Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000 m üNN)
  • Note on connection type: Refer to the information on the conductor cross-sections in the "Axioline F: System and Installation" user manual.
  • Special features: Extreme conditions version
  • CCC / China-Ex: CCC / China-Ex
  • Name of input: Analogue inputs
  • Input description: Inputs for thermocouples or linear voltage
  • Number of inputs: 8 + 1 (8 inputs for thermocouples or linear voltage, additional 1 input -5 V to +5 V )
  • Measurement principle: Sigma-Delta-method
  • Note on dimensions: The depth applies when using a TH 35-7.5 mounting rail (according to EN 60715).
  • Analogue::: Analogue:
  • Input filter time: 40 ms; 60 ms; 100 ms; 120 ms (adjustable)
  • Supply voltage 24 V DC
  • UL Ex, USA / Canada: UL Ex, USA / Canada
  • 24-bit A/D converter resolution
  • Suitable sensor types (RTD): Pt 100 (4 external reference points, can also be used as sensor input)
  • SUITABLE SENSOR TYPES (TC): U, T, L, J, E, K, N, S, R, B C, W, HK
  • Module
  • Input address space: 18 bytes
  • Output address space: 18 bytes
  • Need for parameter data: 20 bytes
  • Need for configuration data: 7 bytes
  • Potential separation/insulation of the voltage ranges: Potential separation/insulation of the voltage ranges
  • Measured value display 16 bit (15 bit + sign)
  • Test voltage: 24 V supply (peripheral) / Functional ground: 500 V AC, 50 Hz, 1 min.
  • Axioline F-Local bus: Axioline F-Local bus
  • Tolerance, relative: Typical. 0.01 % ( K-type thermocouple, NiCr-Ni); see tolerance tables
  • Tolerance, absolute: Type. ± 0.19 K (thermocouple type K, plus tolerance of the reference junction); see tables for tolerance specifications
  • Potential: Supply of the Axioline F-local bus (UBus): Potential: Supply of the Axioline F-local bus (UBus)
  • Potential: Infeed for analog modules (UA): Potentials: Infeed for analog modules (UA)
  • Test voltage: 5 V supply of local bus (UBus) / 24 V supply (peripheral): 500 V AC, 50 Hz, 1 min.
  • Test voltage: 5 V supply of local bus (UBus) / functional ground: 500 V AC, 50 Hz, 1 min.
  • Axioline F-plug: Axioline F-plug
  • Test (pollutant): Test (pollutant gas)
  • ISA-71.04-2013 G3 Harsh Group A;IEC 60068-2-60:2015 Method 4
  • Humidity (relative): 75% ±3%
  • Volume concentration H2S (hydrogen sulphide): 50 ppb
  • Volume concentration NO2 (nitrogen dioxide): 1250 ppb
  • Volume concentration Cl2 (chlorine): 10 ppb
  • Volume concentration SO2 (sulfur dioxide): 300 ppb
Product type

Temperature module

Type

AXL F UTH8 XC 1F

No. of inputs (max.)

9

Operating voltage

24 V DC

5 V DC

Height

126.1 mm

Length

54 mm

Width

53.6 mm

IP20

Dim

(L x W x H) 54 x 53.6 x 126.1 mm

Connection method

2-core

Connection

Push-in wire connector

Max. current consumption

180 mA

Manufacturer part #

2702464

Type

modular block

Fitting type (details)

Carry rail mounting

Max. ambient temperature

70 °C

Min. ambient temperature

-40 °C

Depth

52.59 mm

UKCA

yes

Documents & Downloads

Datasheet

Datasheet 3579365 Phoenix Contact AXL F UTH8 XC 1F 2702464 Temperature module 24 V DC, 5 V DC

User & Safety Instructions

User & Safety Instructions 3579365 Phoenix Contact AXL F UTH8 XC 1F 2702464 Temperature module 24 V DC, 5 V DC

Description

Axioline F, temperature measuring module, analog inputs: 8 (8 inputs for thermocouples or linear voltage, additional 1 input -5  V to +5 V), connection technology: 2-conductor (shielded, twisted pair), transfer speed in local bus: 100 MBit/s, extreme conditions version, protection type: IP20, including bus base module and axioline F-connectors

This text is machine translated.