Siemens 3VA9988-0BA20 Trigger 1 pc(s) (W x H x D) 21.7 x 65.1 x 31.2 mm Piece

1/2
Image similar
Product type
Trigger
Packaging type
Piece
Type
3VA9988-0BA20
Control voltage (max.)
24 V AC
Control voltage range
24 V AC (max)
Datasheet (PDF)
EAN:
Part number:
Item no:
Dispatches on Thu 19 Nov

Sales and shipping:
Conrad ElectronicTerms & Conditions

Number
Total (€ 89.99 / piece)
€ 89.99
prav.tax.untaxed incl. VAT 
plus € 19.99 
prav.priceAvailability.ecoparticipation.cost ...
prav.priceAvailability.privatecopyingfee.cost ...
without further shipping costs 
14-day return policy included

Highlights & Details

TEST DEVICE TD500

Our service for you

Technical specifications

Packaging type

Piece

Product type

Trigger

Type

3VA9988-0BA20

Control voltage (max.)

24 V AC

Control voltage range

24 V AC (max)

Compatible with series

Siemens 3VA series

Compatible with

Siemens

Min. temperature

-20 °C

Max. temperature

+60 °C

IP20

Depth

31.2 mm

Width

21.7 mm

Height

65.1 mm

Dim

(W x H x D) 21.7 x 65.1 x 31.2 mm

Content

1 pc(s)

RoHS-compliant

Yes

Other

UKCA

not relevant

Documents & Downloads

Datasheet

Datasheet 1725095 Siemens 3VA9988-0BA20 Trigger 1 pc(s) (W x H x D) 21.7 x 65.1 x 31.2 mm Piece

User & Safety Instructions

User & Safety Instructions 1725095 Siemens 3VA9988-0BA20 Trigger 1 pc(s) (W x H x D) 21.7 x 65.1 x 31.2 mm Piece

Description

test device TD500 Incl. 2 connection cables pc - TD500, 3VA - TD500 external power supply ACcessory for: 3VA2 Testing and commissioning devices for 3VA molded-case circuit breakers. The TD300 activation and trip box is a mobile, battery-operated local test device. One of its functions is to provide a temporary power supply to the Electronic Trip Units (ETUs) so that they can be operated and parameterized. It is also used to test the tripping function of the molded case circuit breaker. The TD500 mobile test device allows the proper functioning and connections of all connected system components to be tested at the breaker commissioning stage because it is capable of simulating every conceivable cause of breaker tripping. The molded-case circuit breaker behaves as it would in the case of a real trip event. Key features of these accessory components: 1. ETU series 5 and 8 power supply to activate the display. 2. Direct adjustment of parameter settings on ETUs from series 5 and 8. 3. Check for mechanical tripping functions (series 3, 5 and 8 ETU). 4. Check for tripping function L, S, I ,N, G (series 3, 5 and 8 ETU). www.siemens.de/3VA. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.