Technical specifications

  • Wire cross-section with single wire connections: 1.31-5.26 mm²
  • Number of analog outputs: 0
  • Number of analog inputs: 0
  • Number of digital outputs: 1
  • Number of digital inputs: 3
  • Number of Ethernet ports: 2
  • Number of voltage measuring inputs: 4
  • Number of current inputs: 8
  • Reactive power meter: Yes
  • Display: Graphic
  • Remote display: No.
  • Frequency meter: Yes
  • Calibrated: Yes
  • Suitable for RJ plug: Yes
  • Accuracy class reactive power according to IEC 62053-23: Other
  • Accuracy class effective power according to IEC 62053-22: 0.2S
  • Impulse output: Electrical
  • Pulse counter: No.
  • Maximum current (Imax): 20 A.
  • Measurement type load profile: Yes
  • Measured value memory: Yes
  • With audit logging (audit log): Yes
  • With tachometer: No.
  • With firmware signature: No.
  • With communication interface M-Bus: No.
  • With KNX communication interface: No.
  • With RS-485 communication interface: Yes
  • With logging of security events (security event log): Yes
  • With role-based access control (RBAC): No.
  • Mounting type: Front
  • Nominal current (In) 5 A
  • Harmonic measurement: Yes
  • Phase angle (cos phi): Yes
  • Three-conductor/four-wire
  • Apparent power: Yes
  • Voltage type of supply voltage: AC/DC
  • Ammeter: Yes
  • Supports protocol for IEC 61850 Ethernet: Yes
  • Supports protocol for Modbus: Yes
  • Supports protocol for OPC UA PubSub: No.
  • Supports protocol for PROFIBUS: No.
  • Supports protocol for PROFINET IO: No.
  • Supports protocol for other bus systems: Yes
  • Supply voltage AC 50 Hz: 90-415 V
  • Supply voltage AC 60 Hz: 90-415 V
  • Supply voltage DC 110-415 V
  • Voltmeter: Yes
  • Web server with HTTPS transfer protocol: Yes
  • Active power meter: Yes
Product type

Network diagnostics

Manufacturer's standards (no certificate)

Dim

(W x H x D) 96 x 96 x 77.5 mm

Measurement type

3-phase

Features

Troubleshooting

Width

96 mm

Height

96 mm

Interfaces

Ethernet

Depth

77.5 mm

Type

Transformer

Power factor

TRUE

Front mounting

96 mm

Measurement transformer

96 mm

77.5 mm

TRUE

Graphic

20 A

TRUE

TRUE

TRUE

TRUE

3

1

0

0

AC/DC

FALSE

TRUE

TRUE

Other

2

TRUE

TRUE

FALSE

TRUE

FALSE

TRUE

TRUE

TRUE

1.31-5.26 mm²

FALSE

90-415 V

90-415 V

110-415 V

TRUE

TRUE

Electrical

Three conductor/four conductor

TRUE

5 A

0.2S

Other

4

8

TRUE

FALSE

TRUE

FALSE

TRUE

FALSE

TRUE

FALSE

FALSE

FALSE

UKCA

not relevant

Documents & Downloads

Datasheet

Datasheet 3755416 Schneider Electric METSEPM82401 Network diagnostics 3-phase Troubleshooting

User & Safety Instructions

User & Safety Instructions 3755416 Schneider Electric METSEPM82401 Network diagnostics 3-phase Troubleshooting

User & Safety Instructions 3755416 Schneider Electric METSEPM82401 Network diagnostics 3-phase Troubleshooting

Description

The PowerLogic PM82401 is a power analyzer for front installation 96 x 96 mm in low and medium voltage applications with integrated display, AC/DC control voltage and MID compliant. It is designed to ensure the availability and efficiency of your energy-critical equipment. It creates energy transparency and provides data that can be used to complex network quality conditions. With the modular, flexible and powerful ION-technology individual applications can be created for each measuring device. It has high accuracy, multiple communication ports, a web-based user interface and a graphical color display. This mains analyzer also has an integrated power quality analysis and a patented interference direction detection. Certified by independent laboratories for the accuracy of class 0.2S at active power (IEC62052-11, IEC62053-24, IEC62053-22). Also certified for network quality (IEC62586-2, IEC61000-4-30 class S). Cybersecurity features include secure protocols (HTTPS, SFTP, Secure ION), security event logging, syslog protocol. Ability to enable/disable communication ports and support 50 configurable user accounts to manage access. With 512 MB of memory for up to 50 data protocols (800 channels), more than 50 user-definable alarms, waveform recording with up to 256 sampling values/cycle, 1/2-cycle effective value (RMS) logging. The storage can also be used for custom web pages, min/max logs, power trends, and operating hours. Time stamp for events with an accuracy of +/-1ms using time synchronization. Time synchronization methods that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time setting function. 3 digital inputs and one digital output, plus the ability to add up to 4 optional modules. The input/output option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Extensive control voltage of 90-415 VAC / 110-415 VDC. Operating environment from -25 to +70°C, humidity from 5% to 95% and operating altitude up to 3000 m.

This text is machine translated.

Accessories

(*All information is plus legal VAT)

The necessary accessories are required to use the article as described.

More interesting products

(*All information is plus legal VAT)