• All things technology
  • Delivery within Europe
  • Right to Cancel applies
  • Specialist retailer since 1923

Sonel MPI-530 Electrical tester VDE standard 0100

1/4
Datasheet (PDF)
EAN:
Part number:
Item no:
Available soon

Sales and shipping:
Conrad ElectronicTerms & Conditions

Number
Total (€ 2,995.00 / piece)
€ 2,995.00
prav.tax.untaxed incl. VAT 
plus € 19.99 
prav.priceAvailability.ecoparticipation.cost ...
prav.priceAvailability.privatecopyingfee.cost ...
without further shipping costs 
14-day return policy included

Highlights & Details

VDE 0100 Installation Tester MPI-530

  • Loop impedance measurement with max. 41 A at 415 V
  • Loop impedance test without tripping the RCD
  • Short-circuit current calculation
  • Insulation resistance measurement with max. 1000 V up to 10 GΩ
  • Protective earth resistance measurement with ± 200 mA
  • RCD/FI type AC, A and B up to 1000 mA
  • TRMS current measurement up to 400 A
  • AC voltage measurement up to 500 V
  • Effective, apparent and reactive power measurement including p.f.
  • Earthing measurement with 2 clip-on ammeter without disconnecting of the erders by the wenner Method Method
  • Specific earth resistance ρ
  • Lighting Measurement
  • Rotary field indicator;
  • Power quality analysis

Technical specifications

  • "Area loop impedance measurement ZL-PE, ZL-N, ZL - L 0.000... 19,999 Ω: Resolution 0.001 Ω, accuracy: ± (5% v.M. such + 30 digits); range loop impedance measurement ZL-PE, ZL-N, ZL-L 20.00 ... 199.99 Ω: Resolution: 0.01 Ω, accuracy: ± (5% v.M. such + 30 digits); range loop impedance measurement ZL-PE, ZL-N, ZL-L200...1999.9 Ω: Resolution: 0.1 Ω, accuracy: ± (5% v.M. such + 30 digits); voltage ranges: 95...270 V for ZL-PE, ZL-N and 95 … 440 V for ZL-L; frequency: 45 … 65 Hz; range loop impedance measurement ZL-PE without RCD tripping 0.00... 19.99 Ω: Resolution: 0.01 Ω, accuracy: ± (6% v.M. such + 10 digits); range without RCD tripping loop impedance measurement ZL-PE 20... 199 Ω: Resolution: 0.1 Ω, accuracy: ± (6% v.M. such + 5 digits); range loop impedance measurement ZL-PE without RCD tripping 200... 1999 Ω: Resolution: 1 Ω, accuracy: ± (6% v.M. such + 5 digits); range earthing resistance measurement RE: 0.00...9.99 Ω, Resolution: 0.01 Ω, accuracy: ± (2% v.M. such + 4 digits); range earthing resistance measurement RE: 10.00... 99.9 Ω, Resolution: 0.1 Ω, accuracy: ± (2% v.M. such + 3 digits); range earthing resistance measurement RE: 100...999 Ω: Resolution: 1 Ω, accuracy: ± (2% v.M. such + 3 digits); range earthing resistance measurement RE: 1.00...1.99 kΩ: Resolution: 0.01 kΩ, accuracy: ± (2% v.M. such + 3 digits); range ground measurements with pliers: 0.00...9.99 Ω, Resolution: 0.01 Ω, accuracy: ± (8% v.M. such + 4 digits); range ground measurements with pliers: 10.0...99.9 Ω, resolution 0.1 Ω, accuracy: ± (8% v.M. such + 4 digits); range ground measurements with pliers: 100...999 Ω, resolution: 1 Ω, accuracy: ± (8% v.M. such + 4 digits); range ground measurements with pliers 1.00...1.99 kΩ: Resolution: 0.01 kΩ, accuracy: ± (8% v.M. such + 4 digits); range ground measurements with 2 pliers 0.00...9.99 Ω: Resolution: 0.01 Ω, accuracy: ± (10% v.M. such + 4 digits); range ground measurements with 2 pliers 10...19.9 Ω: Resolution: 0.1 Ω, accuracy: ± (10% v.M. such + 4 digits); range ground measurements with 2 pliers 20...99.9 Ω: Resolution: 0.1 Ω, accuracy: ± (20% v.M. such + 4 digits); range specific earth resistance ρ 0.00...9.99 Ωm: Resolution: 0.1 Ωm, Accuracy: depending on RE; range specific earth resistance ρ 100...999 Ωm: Resolution: 1 Ωm, Accuracy: depending on RE; range specific earth resistance ρ 1.00...9.99 kΩm: Resolution: 0.01 kΩm, Accuracy: depending on RE; range specific earth resistance ρ 10.0...99.9 kΩm: Resolution: 0.1 kΩm, Accuracy: depending on RE;Phase sequence indicator UL-L: 95...500 V, 45...65 Hz; tripping time RCDnormal 0.5* In: Range: 0...300 ms, resolution: 1 ms, Accuracy: [± (2% v.M. such + 2 digits), RCD In = 10 mA and 0.5* In ± (2% v.M. such + 3 digits)]; tripping time RCDnormal 1 * In: Range: 0...300 ms, resolution: 1 ms, Accuracy: [± (2% v.M. such + 2 digits), RCD In = 10 mA and 0.5* In ± (2% v.M. such + 3 digits)]; tripping time RCDnormal 2 * In: Range: 0...150 ms, resolution: 1 ms, Accuracy: [± (2% v.M. such + 2 digits), RCD In = 10 mA and 0.5* In ± (2% v.M. such + 3 digits)]; tripping time RCDnormal 5* In: Range: 0...40 ms: Resolution: 1 ms, Accuracy: [± (2% v.M. such + 2 digits), RCD In = 10 mA and 0.5* In ± (2% v.M. such + 3 digits)]; tripping time RCDselektiv 0.5* In: Range: 0...500 ms, resolution: 1 ms, Accuracy: [± (2% v.M. such + 2 digits), RCD In = 10 mA and 0.5* In ± (2% v.M. such + 3 digits)]; tripping time RCDselektiv 1 * In: Range: 0...500 ms, resolution: 1 ms, Accuracy: [± (2% v.M. such + 2 digits), RCD In = 10 mA and 0.5* In ± (2% v.M. such + 3 digits)]; tripping time RCDselektiv 2 * In: Range: 0...200 ms, resolution: 1 ms, Accuracy: [± (2% v.M. such + 2 digits), RCD In = 10 mA and 0.5* In ± (2% v.M. such + 3 digits)]; tripping time RCDselektiv 5* In: Range: 0...150 ms, resolution: 1 ms, Accuracy: [± (2% v.M. such + 2 digits), RCD In = 10 mA and 0.5* In ± (2% v.M. such + 3 digits)]; tripping current RCD type AC 10 mA: Range: 3.3... 10.0 mA, resolution 0.1 mA, Measuring current: 0.3...1,0xIn, Accuracy: ±5% In; tripping current RCD type AC 30 mA: Range: 9.0... 30.0 mA, resolution 0.1 mA, Measuring current: 0.3...1,0xIn, Accuracy: ±5% In; tripping current RCD type AC 100 mA: Range: 33.0...100 mA, resolution 0.1 mA, Measuring current: 0.3...1,0xIn, Accuracy: ±5% In; tripping current RCD type AC 300 mA: Range: 90...300 mA, resolution: 1 mA, Measuring current: 0.3...1,0xIn; accuracy: ±5% In; tripping current RCD type AC 500 mA: Range: 150 - 500 mA, resolution 0.1 mA, Measuring current: 0.3...1,0xIn, Accuracy: ±5% In; tripping current RCD type AC 1000 mA: Range: 330...1000 mA, resolution: 1 mA, Measuring current: 0.3...1,0xIn accuracy: ±5% In; tripping current RCD TYPE A 10 mA: Range: 3.5...20.0 mA, resolution 0.1 mA, Measuring current: 0.35...2,0xIn accuracy: ±10% In; tripping current RCD type A 30mA: Range: 10.5...42.0 mA, resolution 0.1 mA, Measuring current: 0.35...1,4,0 xIn, Accuracy: ±10% In; tripping current RCD TYPE A 100mA: Range: 35.0... 140.0 mA, resolution: 1 mA, Measuring current: 0.35...1,4xIn accuracy: ±10% In; tripping current RCD TYPE A 300mA: Range: 105...420 mA, resolution: 1 mA, Measuring current: 0.35...1,4xIn, Accuracy: ±10% In; tripping current RCD TYPE A 500mA: Range: 175...700 mA, resolution: 1 mA, Measuring current: 0.35...1,4xIn, Accuracy: ±10% In; RCD Type B: see data sheet; rated range - insulation resistance 50 V: 50 kΩ...250 MΩ; rated range - insulation resistance 100 V: 100 k...500MΩ; rated range - insulation resistance 250 V: 250 kΩ... 1 GΩ; rated range - insulation resistance 500 V: 500 kΩ...2 GΩ; rated range - insulation resistance 1000 V: 1 MΩ... 9.99 GΩ; range insulation resistance measurement 0...1999 kΩ: Resolution: 1 kΩ, accuracy: ± (3% v.M. such + 8 digits); range insulation resistance measurement 2.00... 19.99 MΩ: Resolution: 0.01 MΩ, accuracy: ± (3% v.M. such + 8 digits); range insulation resistance measurement 20...199 MΩ: Resolution: 0.1 MΩ, accuracy: ± (3% v.M. such + 8 digits); range insulation resistance measurement 200...999 MΩ: Resolution: 1 MΩ, accuracy: ± (3% v.M. such + 8 digits); range insulation resistance measurement 1.00...9.99 GΩ: Resolution: 0.01 GΩ, accuracy: ± (4% v.M. such + 6 digits); range protective earth resistance measurement ± 200 mA 0.00... 19.99 Ω: Resolution: 0.01 Ω, accuracy: ± (2% v.M. such + 3 digits); range protective earth resistance measurement ± 200 mA 20.00... 199.9 Ω: Resolution: 0.1 Ω, accuracy: ± (2% v.M. such + 3 digits); range protective earth resistance measurement ± 200 mA 200...400 Ω: Resolution: 1 Ω, accuracy: ± (2% v.M. such + 3 digits); range current measurement m. Pliers: C-3, C-6: 0.0... 99.9 mA, resolution 0.1 mA, accuracy: ± (5% v.M. such + 3 digits); range current measurement m. Pliers: C-3, C-6: 100...999 mA, resolution: 1 mA, accuracy: ± (5% v.M. such + 3 digits); range current measurement m. Pliers: C-3, C-6, F-1, F-2, F3: 1.00...9.99 A, resolution 0.01 A, Accuracy: [± (5% v.M. such + 5 digits for C-3, C-6) and ± (0.1% + 2 Digits F. F-1, F-2, F-3)]; range current measurement m. Pliers: C-3, C-6, F-1, F-2, F3: 10.00... 99.9 A, resolution 0.1 A, Accuracy: [± (5% v.M. such + 5 digits for C-3, C-6) and ± (0.1% + 2 Digits F. F-1, F-2, F-3)]; range current measurement m. Pliers: C-3, C-6, F-1, F-2, F3: 100,...999 A. resolution: 1 A, Accuracy: [± (5% v.M. such + 5 digits for C-3, C-6) and ± (0.1% + 2 Digits F. F-1, F-2, F-3)]; range current measurement m. Pliers: C-3, C-6, F-1, F-2, F3: 1.00...3.00 kA, resolution 0.01 kA, Accuracy: [± (5% v.M. such + 5 digits for C-3, C-6) and ± (0.1% + 2 Digits F. F-1, F-2, F-3)]; range for effective. Blind.-apparent power (P, Q, S) and P.f. 0...999 W: Resolution: 1 kW, accuracy: ± (7% v.M. such + 3 digits); range for effective. Blind.-apparent power (P, Q, S) and p.f. 1.00...9.99 kW: Resolution: 0.01 kW, accuracy: ± (7% v.M. such + 3 digits); range for effective. Blind.-apparent power (P, Q, S) and P.f. 10...99.9 kW: Resolution: 0.1 kW, accuracy: ± (7% v.M. such + 5 digits); range for effective. Blind.-apparent power (P, Q, S) and p.f. 100...999 kW: Resolution: 1 kW, accuracy: ± (7% v.M. such + 5 digits); range for effective. Blind.-apparent power (P, Q, S) and P.f. 1...1.50 AM: Resolution: 0.01 AM, accuracy: ± (7% v.M. such + 5 digits); range p.f. 0.00 1.00, Resolution: 0.01; range Harmonious... 0.0...300V, Resolution: 0.1 V, order: 1.2...15, accuracy: ± (5% v.M. such + 3 digits); range Harmonious 0.0...300V, Resolution: 0.1 V, order: 16...40, accuracy: ± (5% v.M. such + 10 digits); range Harmonious 300...500 V: Resolution: 1 V, order and accuracy DC range 0.0...300 V; THD regarding. 1. Harmonious: see data sheet; lighting measurement: see data sheet
Product type

Electrical tester

Manufacturer's standards (no certificate)

Reading category

CAT III 600 V

CAT IV 300 V

Interfaces

USB

Dim

(L x W x H) 310 x 455 x 180 mm

Weight

6.48 kg

IP54

Reading range (VDE)

Insulation resistance

Loop impedance

Wave impedance

Active power

Apparent power

Reactive power

Power factor

Resistance

Earth leakage resistance

Touch voltage

Voltage

Current

Frequency

Show more
DIN standard

DIN IEC 60364

Display type

Digital (LCD)

Width

455 mm

Height

180 mm

Length

310 mm

Voltage supply

Battery

Memory

Yes

Type

MPI-530

VDE standard

0100

Features

RCD/FI testing

Documents & Downloads

Datasheet

Datasheet 1427980 Sonel MPI-530 Electrical tester VDE standard 0100

User & Safety Instructions

User & Safety Instructions 1427980 Sonel MPI-530 Electrical tester VDE standard 0100

Description

Supreme standard DIN VDE 0100/0105 test device MPI-530 of sonel the complete testing of electric installations as well as industrial plants of all kinds. The outstanding extensions to its predecessor model is the advanced earthing measurement with 2 pliers without Erdauftrennung, a lighting knife and the possibility of a Power Quality Analysis through recording of photoconductor, voltage and power, as well as PF, harmonious, p.f. and THD. A master data entry with this model through a Bluetooth keyboard is also possible on site.

This text is machine translated.

Features

  • Robust rubber-protected IP54 housing
  • CAT IV 300V
  • CAT II 600 V
  • Test Leads
  • Push Rod
  • Earthing measuring accessories such as auxiliary electrodes, tongs and measuring lines for spindles
  • Universal rotary current accessories such as CEE-adapter 16 A and 32 A 4- or 5-pin
  • Lighting knife
  • Clamp-on ammeter for Power Quality Analysis
  • Bluetooth
  • Uni-Schutzkontakt Adapter
  • USB cable
  • Bag
  • Rechargeables
  • Protocol software Sonel Reader

Scope of delivery

  • Adapter with UNI-earthing contact plug (WS-03)
  • Test lead with banana sockets, 1.2 m, yellow
  • Test lead with banana sockets 1.2 m, blue
  • Test lead with banana sockets, 1.2 m, red
  • Test lead with banana sockets 15 m spool, blue
  • Test lead with banana sockets 30 m spool, red
  • Measuring tip with banana socket
  • Yellow
  • Measuring tip with banana socket
  • Red
  • Measuring tip with banana socket
  • Blue
  • Alligator clip K02, yellow
  • Alligator clip K02, yellow
  • Ground spike (red), 0.3 m
  • L2 carrying case
  • Strap
  • Battery charger Z7
  • USB cable
  • Cable for battery charger
  • Charging cable for car cigarette lighter (12V)
  • Battery NIMH 4.8V 4,2ah
  • Sonel Reader software
  • User manual
  • Kaliberierzertifikat

Accessories

(*All information is plus legal VAT)

The necessary accessories are required to use the article as described.