VDE 0100 Installation Tester MPI-502

  • Loop impedance measurement: ZL-PE, ZL-N, ZL-L at the mains voltage up to 415 V
  • Measuring current: 7.6 A/230 V and 13 A/400 V
  • Loop impedance test without tripping the RCD
  • RCD/FI testing of type AC, etc.
  • Protective earth resistance measurement ± 200 mA
  • AC voltage measurement
  • Frequency measurement.
  • Automatic reversal of L and N
  • Wireless data transmission is possible
  • Memory for 990 measured values
  • Test device according to IEC 60364-6-61

Technical specifications

  • Range loop impedance measurement ZL-PE, ZL-N, ZL-L 0.00... 19.99 Ω: Resolution 0.01 Ω, accuracy: ± (5% v.M. such + 3 digits); range loop impedance measurement ZL-PE, ZL-N, ZL-L 20.0... 199.9 Ω: Resolution: 0.1 Ω, accuracy: ± (5% v.M. such + 3 digits); range loop impedance measurement ZL-PE, ZL-N, ZL-L200 ... 1999 Ω: Resolution: 1 Ω, accuracy: ± (5% v.M. such + 3 digits); voltage ranges: 180 … 270 V for ZL-PE, ZL-N and 180…460 V for ZL-L; frequency: 50 Hz, 60 Hz; range loop impedance measurement ZL-PE without tripping the RCD 0.00... 19.99 Ω: Resolution: 0.01 Ω, accuracy: ± (6% v.M. such + 10 digits); range loop impedance measurement ZL-PE without tripping the RCD 20...199 Ω: Resolution: 0.1 Ω, accuracy: ± (6% v.M. such + 5 digits); range loop impedance measurement ZL-PE without tripping the RCD 200... 1999 Ω: Resolution: 1 Ω, accuracy: ± (6% v.M. such + 5 digits); tripping time RCDnormal 0.5* In: Range: 0...300 ms, resolution: 1 ms, accuracy: ± (2% v.M. such + 2 digits); tripping time RCDnormal 1 * In: Range: 0...300 ms, resolution: 1 ms, accuracy: ± (2% v.M. such + 2 digits); tripping time RCDnormal 2 * In: Range: 0...150 ms, resolution: 1 ms, accuracy: ± (2% v.M. such + 2 digits); tripping time RCDnormal 5* In: Range: 0...40 ms: Resolution: 1 ms, accuracy: ± (2% v.M. such + 2 digits); tripping time RCDselektiv 0.5* In: Range: 0...500 ms, resolution: 1 ms, accuracy: ± (2% v.M. such + 2 digits); tripping time RCDselektiv 1 * In: Range: 0...500 ms, resolution: 1 ms, accuracy: ± (2% v.M. such + 2 digits); tripping time RCDselektiv 2 * In: Range: 0...200 ms, resolution: 1 ms, accuracy: ± (2% v.M. such + 2 digits); tripping time RCDselektiv 5* In: Range: 0...150 ms, resolution: 1 ms, accuracy: ± (2% v.M. such + 2 digits); tripping current RCD type AC 10 mA: Range: 3.3... 10.0 mA, resolution 0.1 mA, Measuring current: 0.3...1,0xIn, Accuracy: ±5% In; tripping current RCD type AC 30 mA: Range: 9.0... 30.0 mA, resolution 0.1 mA, Measuring current: 0.3...1,0xIn, Accuracy: ±5% In; tripping current RCD type AC 100 mA: Range: 33.0... 100.0 mA, resolution: 1 mA, Measuring current: 0.3...1,0xIn, Accuracy: ±5% In; tripping current RCD type AC 300 mA: Range: 90...300.0 mA, resolution: 1 mA, Measuring current: 0.3...1,0xIn, Accuracy: ±5% In; tripping current RCD type AC 500 mA: Range: 150 - 500,0 mA, resolution: 1 mA, Measuring current: 0.3...1,0xIn, Accuracy: ±5% In; tripping current RCD TYPE A 10 mA: Range: 4...20.0 mA, resolution 0.1 mA, Measuring current: 0.35...2,0xIn, Accuracy: ±10% In; tripping current RCD type A 30mA: Range: 12.5... 42.0mA, resolution 0.1 mA, Measuring current: 0.35...1,4,0 xIn, Accuracy: ±10% In; tripping current RCD TYPE A 100mA: Range: 40.0... 140.0 mA, resolution: 1 mA, Measuring current: 0.35...1,4xIn, Accuracy: ±10% In; tripping current RCD TYPE A 300mA: Range: 120...420 mA, resolution: 1 mA, Measuring current: 0.35...1,4xIn, accuracy: ± 10% In; range protective earth resistance measurement ± 200 mA 0.00... 19.99 Ω: Resolution: 0.01 Ω, accuracy: ± (2% v.M. such + 3 digits); range protective earth resistance measurement ± 200 mA 20.00... 199.9 Ω: Resolution: 0.1 Ω, accuracy: ± (2% v.M. such + 3 digits); range protective earth resistance measurement ± 200 mA 200...400 Ω: Resolution: 1 Ω, accuracy: ± (2% v.M. such + 3 digits); earth resistance measurement RE for RCD 10 mA: range 0.01...5.00 kΩ, resolution 0.01 kΩ, measuring current 4 mA, accuracy: 0...+10% v.M. such ±8 digits; earth resistance measurement RE for RCD 30 mA: range 0.01...1.66 kΩ, resolution 0.01 kΩ, Measuring current: 12 mA, accuracy: 0...+10% v.M. such ± 5 digits; earth resistance measurement RE for RCD 100 mA: Range: 1...500 Ω; Resolution: 1 Ω, measuring current 40 mA, accuracy: 0...+5% v.M. such ± 5 digits; earth resistance measurement RE for RCD 300 mA: Range: 1...166 Ω, resolution: 1 Ω, Measuring current: 120mA, accuracy: 0...+5% v.M. such ± 5 digits; earth resistance measurement RE for RCD 500 mA: Range: 1...100 Ω, resolution: 1 Ω, measuring current 200 mA, accuracy: 0...+5% v.M. such ± 5 digits); Range Contact Voltage 0... 9.9 V, Resolution: 0.1 V, Measuring current: 0.4x in, Accuracy: 10% v.M. such ± 5 digits; Range Contact voltage 10...99.9 V, Resolution: 0.1 V, Measuring current: 0.4x in, Accuracy: 0...15% v.M. such; range voltage measurement 0.0... 299,9 V, Resolution: 0.1 V, accuracy: ± (2% v.M. such + 6 digits); range Voltage Measurement 300...500 V, Resolution: 1 V, accuracy: ± (2% v.M. such + 2 digits); range frequency 45 … 65 Hz: Resolution: 0.1 Hz, accuracy: ± (0.1% v.M. such + 1 digits)
Product type

Electrical tester

Manufacturer's standards (no certificate)

Reading category

CAT IV 300 V

Interfaces

USB

Dim

(L x W x H) 160 x 305 x 265 mm

Weight

1.88 kg

IP67

Reading range (VDE)

Loop impedance

Wave impedance

Resistance

Earth leakage resistance

Touch voltage

Voltage

Current

Frequency

DIN standard

DIN IEC 60364

Display type

Digital (LCD)

Accuracy

0.1 %

Width

305 mm

Height

265 mm

Length

160 mm

Test procedure

automated

Voltage supply

Battery

Memory (space)

990

Memory

Yes

Type

MPI-502

VDE standard

0100

Features

RCD/FI testing

Documents & Downloads

Datasheet

Datasheet 1427976 Sonel MPI-502 Electrical tester VDE standard 0100

User & Safety Instructions

User & Safety Instructions 1427976 Sonel MPI-502 Electrical tester VDE standard 0100

Description

The VDE 0100 tester MPI-502 of Sonel, is the smallest and handlichste version of the MPI-series. It is ideal for a quick check of RCDs and fuses in installations and electrical systems. The perfect combination of size and measurement technology, make the MPI-502 to the test device for any tool case.

This text is machine translated.

Features

  • Robust rubber-protected IP67 housing; multimeter format; CAT IV 300 V; Prufleitungungen with banana sockets or similar test prods. alligator clips; data transmission via ODER-1-Adapter; carrying case; batteries; protocol software Sonel Reader

Scope of delivery

  • Test lead with UNI earthing contact plug (WS-05)
  • Test lead with banana sockets 1.2 m, red
  • Test lead with banana sockets 1.2 m, yellow
  • Test lead with banana sockets 1.2 m, blue
  • Measuring tip with banana jack red
  • Measuring tip with banana jack blue
  • Alligator clip K02 yellow
  • OR-1 receiver
  • Carrying Case M6
  • Strap
  • Calibration certificate
  • User manual
  • Batteries
  • Software Sonel Reader

Frequently Bought Together

(*All information is plus legal VAT)
Total price:

€ 1,888.00*

Accessories

(*All information is plus legal VAT)

The necessary accessories are required to use the article as described.

More interesting products

(*All information is plus legal VAT)