• All things technology
  • Delivery within Europe
  • Right to Cancel applies
  • Specialist retailer since 1923

Weidmüller WAS6 TTA EX 8964310000 Signal converter 1 pc(s)

Product type
Signal converter
Input signal (current) (max.)
50 mA
Input signal (voltage) (max.)
50 V
Type
WAS6 TTA EX
Dim
(L x W) 100 mm x 45 mm
Datasheet (PDF)
EAN:
Part number:
Item no:
Unavailable

Sales and shipping:
Conrad ElectronicTerms & Conditions

Highlights & Details

Signal Converter/disconnector, limit value monitoring

  • What 6 TTA EX
  • A hexagonal symbol with the inscription 'Ex', which indicates areas with explosion hazards.

Technical specifications

  • Depth: 112.4 mm
  • Net weight 265 g
  • Operating temperature: 40 °C - +70 °C
  • Storage temperature: -40 °C to +85 °C.
  • Number of inputs: 1
  • Potentiometer 100 Ω-100 kΩ
  • Sensor: Thermocouples: B, E, J, K, L, N, R, S, T (IEC 60584), PT100, Pt1000, (EN 60571) Ni100, Ni1000, (JIS1604), Cu10, Cu25, CU50, Cu100 (DIN 43760) 2-/3-/4-conductor
  • Accuracy < : 0.1% span (DC, RTD), 0.2% span (or 1 °C) + CJ error
  • Input frequency: Adjustable, 2 Hz - 100 kHz
  • Output type: 2 x 1 changeover contact (hard gold plated), process interrupts (4-fold) with hysteresis, with alarm delay (configurable) 0…180 s.
  • Switching voltage: 250 V/AC
  • Power consumption: 3.5 W
  • Jump response time: 50 ms - 1 s (RTD, mV inputs), 110 ms - 1 s (V, mA inputs)
  • Surge voltage 6 kV
  • Load resistance Voltage: > 10 kΩ at 0 V-10 V / > 20 kΩ at -10...+10 V.
  • Sensor supply: 24 V/DC / 22 mA
  • Wire stripping length rated connection 7 mm
  • Clearance and creepage distance > 5.5 mm (1 mm input/output)
  • Tightening torque, min.: 0.4 Nm
  • Tightening torque, max. 0.5 Nm
Type

WAS6 TTA EX

Product type

Signal converter

Input signal (current) (max.)

50 mA

Input signal (voltage) (max.)

50 V

Dim

(L x W) 100 mm x 45 mm

Connection

Screws

Output (current)

0 mA-20 mA

Operating voltage

300 V (max)

Max. operating voltage

300 V

Load

700 Ω

Input signal (voltage)

50 V/DC

Input signal (current)

50 mA

Content

1 pc(s)

Configuration

Software

Width

45 mm

Length

100 mm

RoHS-compliant

Yes

Type

PT100

PT1000

Supply voltage (num.)

240 V DC

Cross section (inflexible) (max.)

2.5 mm²

Cross section (inflexible) (min.)

0.5 mm²

Depth

112.4 mm

Type

What 6 TTA EX

Weight

288 g

Documents & Downloads

Datasheet

Datasheet 258842 Weidmüller WAS6 TTA EX 8964310000 Signal converter 1 pc(s)

User & Safety Instructions

User & Safety Instructions 258842 Weidmüller WAS6 TTA EX 8964310000 Signal converter 1 pc(s)

Description

Signal Converter/disconnector, limit value monitoring. Wave Series, signal converters/disconnector, limit value monitoring. What WAZ 6 TTA is a universal PC-configurable signal converter and limit switches. It is separator, generator, Linea Risi more and limit switch in a module.. The combination of best features and exceptional configuration option makes the TTA unique.  The TTA works in a wide range of ambient temperature and voltage range precise and stable with all the common sensor types. Universal input signals: temperature signals, such as resistance thermometers, thermocouples and potentiometer, frequency generator and DC voltage and current signals, current loop fed or passive input, wide-range power supply 18…264 V AC/DC. Custom linearization. Inputs and outputs are PC-configurable. Analogue and relay output combined. Ambient temperature range -40 °C - 70 °C. The connection to the PC is made via the CBX200 USB interface. The WAZ 6 TTA is optional also with what/ATEX Zone 2 and UL C1D 2 certification.

This text is machine translated.

What kind of Transducers (Misc.) are you looking for?