Technical specifications

  • Axioline F product family
  • Modular design: Block modules
  • Push-in connection
  • Conductor cross-section flexible: 0.2 mm² ... 1.5 mm².
  • Conductor cross-section rigid: 0.2 mm² ... 1.5 mm².
  • Wire cross-section AWG: 24 ... 16
  • Width 53.6 mm
  • Height: 126.1 mm
  • Depth: 54 mm
  • Ambient conditions: Environmental conditions
  • Protection class: IP20
  • Ambient temperature (operation): -25 °C ... 60 °C (standard and applications with UL approval);-40 °C ... 70 °C (Extended, see chapter "Successfully tested: Use under extreme environmental conditions" in data sheet.)
  • Ambient temperature (storage/transport): -40 °C ... 85 °C
  • Mounting type: Rail mounting
  • Insulation properties: Insulation properties
  • OVERVOLTAGE CATEGORY II (IEC 60664-1, EN 60664-1)
  • Pollution level 2 (IEC 60664-1, EN 60664-1)
  • Permissible air humidity (operation): 5 % ... 95% (no condensation)
  • Name of connection: Axioline F-plug
  • Stripped length: 8 mm
  • Installation position: Arbitrary (no temperature derating)
  • Transmission speed 100 MBit/s
  • Maximum power loss at rated conditions 3 W.
  • Testing period: 21 days
  • PROTECTION CLASS III (IEC 61140, EN 61140, VDE 0140-1)
  • Output voltage 24 V
  • Number of interfaces: 2
  • Air pressure (operation): 70 kPa ... 106 kPa (up to 3000 m üNN)
  • Delivery scope: Inclusive of bus base module and Axioline F-plugs
  • Supply voltage range: 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Connection technology: Connection technology
  • Permissible humidity (storage/transport): 5 % ... 95% (no condensation)
  • Note for application: Only for industrial use
  • Power consumption: Max. 8 A (up to HW 01, secure externally);max. 16 A (from HW 02, secure externally | If the total current exceeds 8 A, connect the power supply to the infeed connector in parallel via both terminal points!)
  • Rated output voltage 24 V DC
  • Wire connection: Conductor connection
  • Temperature 25 °C ±1 K
  • Protection circuit: Overvoltage protection | electronic (35 V, 0.5 s);reverse polarity protection | parallel diode | with external fuse 5 A (only for commissioning)
  • Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000 m üNN)
  • Note on connection type: Refer to the information on the conductor cross-sections in the "Axioline F: System and Installation" user manual.
  • Usage restriction: Use restriction
  • EMC note: EMC: Class A product, see manufacturer's declaration in the download area
  • Special features: Extreme conditions version
  • Number of outputs: 32
  • Designation output: Digital outputs
  • Note on dimensions: The depth applies when using a TH 35-7.5 mounting rail (according to EN 60715).
  • Digital: Digital:
  • Supply voltage 24 V DC
  • Output voltage in switched off state: Max. 1 V.
  • Limiting of inductive cut-off voltage: -32.8 V ... -15 V
  • Module
  • Input address space: 0 bytes
  • Output address space: 4 bytes
  • Need for parameter data: 1 bytes
  • Need for configuration data: 6 bytes
  • Potential separation/insulation of the voltage ranges: Potential separation/insulation of the voltage ranges
  • Test voltage: 24 V supply (peripheral) / Functional ground: 500 V AC, 50 Hz, 1 min.
  • Nominal load inductive: Max. 12 VA (1.2 H, 48 Ω, at nominal voltage)
  • Nominal load for lamps: Max. 12 W (at nominal voltage)
  • Nominal load resistive: Max. 12 W (48 Ω, at nominal voltage)
  • Reverse EMF resistance to short pulses: Reverse current resistance is limited to 0.5 A for 1 seconds
  • Behaviour in case of inductive overload: Output can be destroyed
  • Overcurrent circuit: 0.7 A and above
  • Axioline F-Local bus: Axioline F-Local bus
  • Potential: Supply of the Axioline F-local bus (UBus): Potential: Supply of the Axioline F-local bus (UBus)
  • Test voltage: 5 V supply of local bus (UBus) / 24 V supply (peripheral): 500 V AC, 50 Hz, 1 min.
  • Test voltage: 5 V supply of local bus (UBus) / functional ground: 500 V AC, 50 Hz, 1 min.
  • Axioline F-plug: Axioline F-plug
  • Test (pollutant): Test (pollutant gas)
  • ISA-71.04-2013 G3 Harsh Group A;IEC 60068-2-60:2015 Method 4
  • Humidity (relative): 75% ±3%
  • Volume concentration H2S (hydrogen sulphide): 50 ppb
  • Volume concentration NO2 (nitrogen dioxide): 1250 ppb
  • Volume concentration Cl2 (chlorine): 10 ppb
  • Volume concentration SO2 (sulfur dioxide): 300 ppb
  • Maximum output current per module: 8 A (to HW 01, protect externally);16 A (from HW 02, save externally | If the total current exceeds 8 A, connect the supply to the infeed connector in parallel via both terminal points!)
  • Load min. 10 kΩ
  • Output current in switched off state: Max. 300 µA
  • Switching frequency: Max. 5500 per second (at resistive nominal load);max. 1 per second (with inductive nominal load);max. 16 per second (with nominal lamp load)
  • Behaviour in case of overload: Switch-off with automatic restart
  • Signal delay: Max. 150 µs (when switched on);max. 200 µs (when switched off | at resistive nominal load)
  • Output current for ground break in switched-off state: < 1 mA
  • Potential: Feed for digital output modules (UO): Potential: Feed for digital output modules (UO)
Product type

Digital module

Type

AXL F DO32/1 XC 1F

No. of outputs (max.)

32

No. of inputs

0 x

No. of outputs

32 x

Max. output current per channel

500 mA

Output signal voltage

24 V

Operating voltage

24 V DC

5 V DC

Height

126.1 mm

Length

54 mm

Width

53.6 mm

IP20

Dim

(L x W x H) 54 x 53.6 x 126.1 mm

Connection method

1-core

Connection

Push-in wire connector

Max. current consumption

16 A

Manufacturer part #

2701230

Type

modular block

Fitting type (details)

Carry rail mounting

Max. ambient temperature

70 °C

Min. ambient temperature

-40 °C

Depth

52.59 mm

UKCA

yes

Documents & Downloads

Datasheet

Datasheet 3579288 Phoenix Contact AXL F DO32/1 XC 1F 2701230 Digital module 24 V DC, 5 V DC

User & Safety Instructions

User & Safety Instructions 3579288 Phoenix Contact AXL F DO32/1 XC 1F 2701230 Digital module 24 V DC, 5 V DC

Description

Axioline F, Digital Output Module, Digital Outputs: 32, 24 VDC, 500 mA, Connection technology: 1-conductor, extreme conditions version, transmission speed in local bus: 100 MBit/s, protection class: IP20, including bus base module and Axioline F-plugs

This text is machine translated.