Earthing measuring device MRU-120

  • 2-, 3- and 4-pin earthing measurement
  • 3-pin. Earthing measurement with a pair of pliers
  • Earthing measurement with 2 pliers without separating of the Erders
  • Specific Erwiderstand
  • Current measurement with clamp-on ammeter
  • Earthing measurement with Auxiliary Electrical Oden RS and RH
  • Protective earth resistance measurement with 200 mA
  • Measurement of interference voltages in networks with 50 Hz, leakage current measurement
  • 60 Hz
  • Measuring voltage 24 V or 50 V
  • The distance in meters (m) or foot (ft)
  • Real time clock (RTC)
  • USB port

Technical specifications

  • Range 3 - and 4-conductor earth ground measurement 0.00... 19.99 Ω: Resolution: 0.01 Ω, accuracy: ± (2% v.M. such + 2 digits); Area 3 and 4-conductor earth measurements 20.0... 199.9 Ω: Resolution: 0.1 Ω, accuracy: ± (2% v.M. such + 2 digits); Area 3 and 4-conductor earth measurements 200... 1999 Ω: Resolution: 1 Ω, accuracy: ± (2% v.M. such + 2 digits); Area 3 and 4-conductor earth measurements 2.0... 9.99 kΩ: Resolution: 0.01 kΩ, accuracy: ± (5% v.M. such + 4 digits); Area 3 and 4-conductor earth measurements 10.0 kΩ... 19.9 kΩ: Resolution: 0.1 kΩ, accuracy: ± (5% v.M. such + 4 digits); test Continuity Measurement: 200 mA; range continuity measurement 0.00... 19.99 Ω: Resolution: 0.01 Ω, accuracy: ± (2% v.M. such + 2 digits); range continuity measurement 20.0... 199.9 Ω: Resolution: 0.1 Ω, accuracy: ± (2% v.M. such + 2 digits); range continuity measurement 200... 1999 Ω: Resolution: 1 Ω, accuracy: ± (2% v.M. such + 2 digits); range continuity measurement 2.0... 9.99 kΩ: Resolution: 0.01 kΩ, accuracy: ± (5% v.M. such + 2 digits); range continuity measurement 10.0 kΩ... 19.9 kΩ: Resolution: 0.1 kΩ, accuracy: ± (5% v.M. such + 2 digits); range resistance measurement with auxiliary electrode 0...999 Ω: Resolution: 1 Ω, accuracy: ± [5% (RS+ RE + RH) + 8 digits]; range resistance measurement with auxiliary electrode 1.00 kΩ... 9.99 kΩ: Resolution: 0.01 kΩ, accuracy: ± [5% (RS+ RE + RH) + 8 digits]; range resistance measurement with auxiliary Electrodes 10.0 kΩ... 19.9 kΩ: Resolution: 0.1 kΩ, accuracy: ± [5% (RS+ RE + RH) + 8 digits]; range ground measurements with 1 clip-on ammeter 0.00... 19.99 Ω: Resolution: 0.01 Ω, accuracy: ± (8% v.M. such + 3 digits); range ground measurements with 1 clip-on ammeter 20.0... 199.9 Ω: Resolution: 0.1 Ω, accuracy: ± (8% v.M. such + 3 digits); range ground measurements with 1 pliers 200... 1999 Ω: Resolution: 1 Ω, accuracy: ± (8% v.M. such + 3 digits); range ground measurements with 2 pliers 0.00... 19.99 Ω: Resolution: 0.01 Ω, accuracy: ± (10% v.M. such + 3 digits); range ground measurements with 2 pliers 20.00... 149.9 Ω: Resolution: 0.1 Ω, accuracy: ± (20% v.M. such + 3 digits); range specific earth resistance 0.0... 199.9 Ωm: Resolution: 0.1 Ωm, Accuracy: depending on v. RE 4-pin, but not cl. than ± 1 Digi; range specific earth resistance 200... 1999 Ωm: Resolution: 1 Ωm, Accuracy: depending on v. RE 4-pin, but not cl. than ± 1 Digi; range specific earthing resistance 2.00... 19.99 kΩm: Resolution: 0.01 kΩm, Accuracy: depending on v. RE 4-pin, but not cl. than ± 1 Digi; range specific earth resistance 20.0...99.9 kΩm: Resolution: 0.1 kΩm, Accuracy: depending on v. RE 4-pin, but not cl. than ± 1 Digi; range specific earth resistance 100...999 kΩm: Resolution: 1 kΩm, Accuracy: depending on v. RE 4-pin, but not cl. than ± 1 Digi; range interference voltages AC/DC 0...100 V: Resolution: 1 V, accuracy: ± (2% v.M. such + 3 digits)
Product type

Earth ground meter

Interfaces

USB

Manufacturer's standards (no certificate)

Data storage

990

IP54

Dim

(L x W x H) 31 x 45.5 x 18 cm

Weight

7.06 kg

Display

Digital

Content

1 pc(s)

Reading category

CAT IV 300 V

Measuring type

Ground spike

Clamp

Width

45.5 cm

Height

18 cm

Length

31 cm

Type

MRU-120

Documents & Downloads

Datasheet

Datasheet 1427987 Sonel MRU-120 Earth ground meter

User & Safety Instructions

User & Safety Instructions 1427987 Sonel MRU-120 Earth ground meter

Description

The earthing measuring device MRU-120 of sonel from the middle-class area of the MRU series is equipped with the basic 2-, 3- and 4-pole earth ground measurement methods. In addition, measurements and using pliers without separating the coils. With the comprehensive range of accessories such as current pliers, 25 m long measuring lines and auxiliary electrode, earthing measurements, the specific earth resistance and PE resistance measurements in any environment and of any earthing and lightning protection system can be carried out.

This text is machine translated.

Features

  • Robust, rubber-protected IP54 housing
  • CAT IV 300V
  • Test leads for reels up to 50 m
  • Alligator Clips
  • Earthing clamp
  • Earth spikes
  • Rechargeables
  • Adapter for power supply
  • car charging adapter
  • Batteries
  • Bag
  • Sonel Reader software

Scope of delivery

  • 4 earth spikes each 30 cm
  • 1 test lead 2.2 m
  • 1 test lead 1.2 m
  • Test line 25 m on reel
  • Test line 25 m on reel
  • Test line 50 m on reel
  • Alligator clip
  • L2 carrying case
  • USB cable
  • Battery Charger Z7
  • Battery NiMH 4.8 V 3 Ah
  • User manual
  • Calibration certificate
  • Sonel Reader software.