• All things technology
  • Delivery within Europe
  • Right to Cancel applies
  • Specialist retailer since 1923

Phoenix Contact 1064665 TTC-6P-3-EX-24DC-UT-I Surge protection device 10 kA 1 pc(s)

Image similar
Datasheet (PDF)
EAN:
Part number:
Item no:
Unavailable

Sales and shipping:
Conrad ElectronicTerms & Conditions

Technical specifications

  • Product family: TERMITRAB complete
  • IEC TEST CLASS C1;C2;C3;D1
  • Model: Two-part rail module can be plugged
  • Message Surge Protection Faulty: Optical
  • NOMINAL VOLTAGE 24 V DC
  • Connection type: screw terminals.
  • M3 screw thread
  • Tightening torque: 0.5 Nm ... 0.6 Nm
  • Conductor cross-section flexible: 0.2 mm² ... 2.5 mm².
  • Conductor cross-section rigid: 0.2 mm² ... 4 mm².
  • Wire cross-section AWG: 24 ... 12
  • Width 6.2 mm +0.1 mm
  • Height: 1.8" (105.8 mm)
  • Depth: 100 mm (including mounting rail 7.5 mm)
  • Colour: Blue (RAL 5015);light gray (RAL 7035)
  • Flammability class according to UL 94 V-0
  • Material: housing: PBT
  • Mechanical Data: Mechanical Data
  • Open side wall: No.
  • Direction of action: Line & Line signal Ground/Shield & optional signal Ground/Shield-Earth Ground
  • Highest continuous voltage UC 30 V DC
  • Rated current 5 A (55 °C)
  • Operating current IC at UC ≤ 5 µA
  • Earth current IPE ≤ 1 µA
  • Total leakage surge current ITtotal (8/20) µs 10 kA
  • Protection level Up (wire): ≤ 68 V (C1 - 1 kV / 500 A);≤ 50 V (C3 - 100 A);≤ 50 V (C3 - 25 A)
  • Protection level Up (wire-earth): ≤ 700 V (C1 - 1 kV / 500 A);≤ 900 V (C2 - 10 kV / 5 kA)
  • Capacity (wire-wire): Typ. 30 pF
  • Capacity (wire-earth): Typ. 30 pF
  • Resistance per path: < 0.1 Ω
  • Required maximum backup fuse: 5 A (F)
  • Surge current (Wire-Earth) C1 - 1 kV / 500 A; C2 - 10 kV / 5 kA; D1 - 500 A
  • Ambient conditions: Environmental conditions
  • Protection class: IP20
  • Ambient temperature (operation): -40 °C ... 85 °C
  • Ambient temperature (storage/transport): -40 °C ... 85 °C
  • Altitude: ≤ 2000 m (amsl)
  • Standards/regulations: IEC 61643-21
  • Note: 2000 + Corrigendum 2001 + A1:2008, modified + A2:2012
  • Mounting type: Mounting rail: TH 35 - 7.5 mm
  • Insulation properties: Insulation properties
  • Over voltage category III
  • Pollution level: 2
  • Insulating material PBT
  • Permissible air humidity (operation): 5 % ... 95 %.
  • Nominal impulse surge current In (8/20) µs (wire-ground): 5 kA
  • Impulse leakage surge current Iimp (10/350) µs (wire-ground) 0.5 kA
  • Response time TA (wire-earth): ≤ 100 ns
  • Impulse reset time (wire-earth): ≤ 500 ms
  • EN 61643-21, EN 61643-21
  • Nominal suppression current In (8/20) µs (wire-wire) 0.5 kA
  • Response time TA (wire-wire): ≤ 1 ns
  • AE insertion loss, sym.: Typ. 0.3 dB (≤ 12 MHz / 150 Ω)
  • Cut-off frequency FG (3 dB), balanced In the 150 Ω system: Typ. 60 MHz
  • Surge current resistance (wire) C1 - 1 kV / 500 A; C3 - 100 A
  • Impulse reset time (wire): ≤ 30 ms
  • Maximum internal capacity CI: Negligible
  • Max. Inner inductance Li: Negligible
  • Maximum input current II: 400 mA (T4 / -40 °C ... +50 °C);250 MA (T4 / -40 °C ... +70 °C);350 MA (T6 / -40 °C ... +35 °C);100 MA (T6 / -40 °C ... +70 °C
  • max. Input voltage UI 30 V DC
  • Conformity/Approvals: Conformity/approvals
  • UL, USA / Canada: Class I, div. 2, GROUPS A, B, C, D T4A
Product type

Surge protection device

Leakage current

10 kA

Type

Mounting rail module can be plugged in two parts

IP20

Manufacturer part #

1064665

Dim

(W x H x D) 6.2 x 105.8 x 100 mm

Width

6.2 mm

Height

105.8 mm

Depth

100 mm

Content

1 pc(s)

UKCA

yes

Documents & Downloads

Datasheet

Datasheet 3562401 Phoenix Contact 1064665 TTC-6P-3-EX-24DC-UT-I Surge protection device 10 kA 1 pc(s)

User & Safety Instructions

User & Safety Instructions 3562401 Phoenix Contact 1064665 TTC-6P-3-EX-24DC-UT-I Surge protection device 10 kA 1 pc(s)

Description

Overvoltage protection device

This text is machine translated.