• All things technology
  • Delivery within Europe
  • Right to Cancel applies
  • Specialist retailer since 1923

Phoenix Contact 1088786 TTC-6-3-HF-F-24AC-PT-I Surge protection device 10 kA Piece 1 pc(s)

Image similar
Datasheet (PDF)
EAN:
Part number:
Item no:
Unavailable

Sales and shipping:
Conrad ElectronicTerms & Conditions

Technical specifications

  • Product family: TERMITRAB complete
  • IEC TEST CLASS C1;C2;C3;D1
  • Designed: Single piece mounting rail module
  • Message Surge Protection Faulty: Optical
  • NOMINAL VOLTAGE 24 V AC
  • Push-in connection
  • Conductor cross-section flexible: 0.2 mm² ... 2.5 mm².
  • Conductor cross-section rigid: 0.2 mm² ... 4 mm².
  • Wire cross-section AWG: 24 ... 12
  • Width 6.2 mm +0.1 mm
  • Height: 1.8" (105.8 mm)
  • Depth: 83.5 mm (including mounting rail 7.5 mm)
  • Colour: Grey (RAL 7042)
  • Flammability class according to UL 94 V-0
  • Material: housing: PBT
  • Mechanical Data: Mechanical Data
  • Open side wall: No.
  • Direction of action: Line & Line signal Ground/Shield & optional signal Ground/Shield-Earth Ground
  • Maximum continuous voltage UC: 43 V DC;30 V AC
  • Rated current 600 mA (40 °C)
  • Earth current IPE ≤ 1 µA
  • Nominal impulse surge current In (8/20) µs: 10 kA
  • Impulse leakage surge current Iimp (10/350) µs 2.5 kA
  • Total leakage surge current ITtotal (8/20) µs 10 kA
  • Protection level Up (wire): ≤ 80 V (C1 - 1 kV / 500 A);≤ 80 V (C1 - 1 kV / 500 A, >1 µs);≤ 150 V (C2 - 10 kV / 5 kA);≤ 70 V (C2 - 10 kV / 5 kA , >1 ΜS);≤ 75 V (C3 - 100 A);≤ 75 V (C3 - 100 A, >1 ΜS)
  • Protection level Up (wire-earth): ≤ 900 V (C1 - 1 kV / 500   A);≤ 100 V (C1 - 1 > kV / 500 A, 1 µs);≤ 1 kV (C2 - 10 kV / 5 kA);≤ 70 V (C2 - 10 kV / 5 kA , >1 ΜS);≤ 1200 V (C3 - 100 A);≤ 70 V (C3 - 100 A, >1 ΜS)
  • Capacity (wire-wire): Typ. 25 pF
  • Capacity (wire-earth): Typ. 50 pF
  • Resistance per path: 1.65 Ω ±20 %
  • Required maximum backup fuse: 630 mA (FF)
  • C1 - 1 kV / 500 A; C2 - 10 kV / 5  kA; C2 - 10 kA; C3 - 100 A; D1 - 2.5 kA
  • Ambient conditions: Environmental conditions
  • Protection class: IP20
  • Ambient temperature (operation): -40 °C ... 85 °C
  • Ambient temperature (storage/transport): -40 °C ... 85 °C
  • Altitude: ≤ 4000 m (amsl)
  • Standards/regulations EN 61643-21
  • Note:2001 + A1:2009 + A2:2013
  • Mounting type: Mounting rail: TH 35 - 7.5 mm
  • Insulation properties: Insulation properties
  • Over voltage category III
  • Pollution level: 2
  • Insulating material PBT
  • Permissible air humidity (operation): 5 % ... 95 % (non-condensing)
  • Response time TA (wire-earth): ≤ 55 ms
  • EN 61643-21, EN 61643-21
  • Response time TA (wire-lead): ≤ 1 ms
  • AE insertion loss, sym.: Typ. 0.3 dB (≤ 10 MHz / 150 Ω)
  • Cut-off frequency FG (3 dB), balanced In the 150 Ω system: Typ. 60 MHz
  • C1 - 1 kV / 500 A; C2 -   100 kV / 5 kA; C2 - 10 kA; C3 - 10 A
Product type

Surge protection device

Leakage current

10 kA

Type

Support rail module one piece

IP20

Manufacturer part #

1088786

Dim

(W x H x D) 6.2 x 105.8 x 83.5 mm

Width

6.2 mm

Height

105.8 mm

Depth

83.5 mm

Content

1 pc(s)

Packaging type

Piece

UKCA

yes

Documents & Downloads

Datasheet

Datasheet 3563777 Phoenix Contact 1088786 TTC-6-3-HF-F-24AC-PT-I Surge protection device 10 kA Piece 1 pc(s)

User & Safety Instructions

User & Safety Instructions 3563777 Phoenix Contact 1088786 TTC-6-3-HF-F-24AC-PT-I Surge protection device 10 kA Piece 1 pc(s)

Description

Overvoltage protection device

This text is machine translated.