• All things technology
  • Delivery within Europe
  • Right to Cancel applies
  • Specialist retailer since 1923

Phoenix Contact 1065316 TTC-6-3-HF-12DC-PT Surge protection device 20 kA 1 pc(s)

Image similar
Datasheet (PDF)
EAN:
Part number:
Item no:
Unavailable

Sales and shipping:
Conrad ElectronicTerms & Conditions

Technical specifications

  • Product family: TERMITRAB complete
  • IEC TEST CLASS C1;C2;C3;D1
  • Designed: Single piece mounting rail module
  • Message Surge Protection Faulty: None
  • NOMINAL VOLTAGE 12 V DC
  • Push-in connection
  • Conductor cross-section flexible: 0.2 mm² ... 2.5 mm².
  • Conductor cross-section rigid: 0.2 mm² ... 4 mm².
  • Wire cross-section AWG: 24 ... 12
  • Width 6.2 mm +0.1 mm
  • Height: 1.8" (105.8 mm)
  • Depth: 69.5 mm (including mounting rail 7.5 mm)
  • Colour: Grey (RAL 7042);light gray (RAL 7035)
  • Flammability class according to UL 94 V-0
  • Material: housing: PBT
  • Mechanical Data: Mechanical Data
  • Open side wall: No.
  • Direction of action: Line & Line signal Ground/Shield & optional signal Ground/Shield-Earth Ground
  • Maximum continuous voltage UC: 15 V DC;10 V AC
  • Rated current 600 mA (40 °C)
  • Operating current IC at UC ≤ 100 µA
  • Earth current IPE ≤ 200 µA
  • Total leakage surge current ITtotal (8/20) µs 10 kA
  • Protection level Up (wire): ≤ 45 V (C1 - 1 kV / 500 A);≤ 85 V (C2 - 10 kV / 5 kA);≤ 30 V (C3 - 100 A)
  • Protection level Up (wire-earth): ≤ 50 V (C1 - 1 kV / 500 A);≤ 90 V (C2 - 10 kV / 5 kA);≤ 30 V (C3 - 100 A)
  • Capacity (wire-wire): Typ. 32 pF
  • Capacity (wire-earth): Typ. 32 pF
  • Resistance per path: 1.65 Ω ±20 %
  • Required maximum backup fuse: 630 mA (FF)
  • C1 - 1 kV / 500 A; C2 -   500 kV / 5 kA; C3 - 100 A; D1 - 10 A
  • Ambient conditions: Environmental conditions
  • Protection class: IP20
  • Ambient temperature (operation): -40 °C ... 85 °C
  • Ambient temperature (storage/transport): -40 °C ... 85 °C
  • Altitude: ≤ 4000 m (amsl)
  • Standards/regulations EN 61643-21
  • Note:2001 + A1:2009 + A2:2013
  • Mounting type: Mounting rail: TH 35 - 7.5 mm
  • Insulation properties: Insulation properties
  • Over voltage category III
  • Pollution level: 2
  • Insulating material PBT
  • Permissible air humidity (operation): 5 % ... 95 %.
  • Nominal impulse surge current In (8/20) µs (wire-ground): 5 kA
  • Impulse leakage surge current Iimp (10/350) µs (wire-ground) 0.5 kA
  • Response time TA (wire-earth): ≤ 1 ns
  • Additional technical data: Additional technical data
  • AE Insertion loss, unbalanced: Type 0.3 dB (≤ 10.5 MHz/150 Ω)
  • Impulse reset time (wire-earth): ≤ 30 ms
  • Max. Total surge current I total max. (8/20) µs 20 kA (1x)
  • EN 61643-21, EN 61643-21
  • Cut-off frequency FG (3 dB), unbalanced (PE) in 150 Ω system: Type. 60 MHz
  • Nominal suppression current In (8/20) µs (wire-wire) 5 kA
  • Response time TA (wire-wire): ≤ 1 ns
  • AE insertion loss, sym.: Typ. 0.3 dB (≤ 8.7 MHz/150 Ω)
  • Cut-off frequency FG (3 dB), balanced In the 150 Ω system: Typ. 60 MHz
  • Surge current (core) C1 - 1 kV / 500 A; C2 - 10 kV / 5 kA; C3 - 100 A
  • Impulse reset time (wire): ≤ 30 ms
Product type

Surge protection device

Leakage current

20 kA

Type

Support rail module one piece

IP20

Manufacturer part #

1065316

Dim

(W x H x D) 6.2 x 105.8 x 69.5 mm

Width

6.2 mm

Height

105.8 mm

Depth

69.5 mm

Content

1 pc(s)

UKCA

yes

Documents & Downloads

Datasheet

Datasheet 3562423 Phoenix Contact 1065316 TTC-6-3-HF-12DC-PT Surge protection device 20 kA 1 pc(s)

User & Safety Instructions

User & Safety Instructions 3562423 Phoenix Contact 1065316 TTC-6-3-HF-12DC-PT Surge protection device 20 kA 1 pc(s)

Description

Overvoltage protection for three signal cores with a common reference potential. For HF-applications and telecommunication interfaces without supply voltage (up to 90 MBit/s). Can be used in safety-related circuits up to SIL 3.

This text is machine translated.