Technical specifications

  • Measurement range contact-free voltage testing 100 - 600 V/AC
Voltage reading range DC (min.)

0.1 mV

Product type

Handheld multimeter

Voltage DC reading range (max.)

600 V

V AC reading range (min.)

0.1 V

V AC reading range (max.)

600 V

Amperage reading range DC (min.)

0.1 mA

A DC reading range (max.)

10 A

A AC reading range (min.)

0.1 mA

Amperage reading range AC (max.)

10 A

Reading range - resistance

0.1 Ω - 2000 kΩ

DC resistance

1 MΩ

AC resistance

1 MΩ

Basic accuracy

0.5 %

Measurement type (details)

Average

Frequency range

50/60 Hz

Interfaces

none

Height

147 mm

Width

76 mm

Weight

260 g

ISO standards

Reading category

CAT III 600 V

Voltage metering

AC/DC

Current reading

AC/DC

Type

EX310

Display

Digital

Display (counts)

2000

Dim

(W x H) 76 mm x 147 mm

Calibration service

5 calibration values per range; VDC. VAC. ADC. AAC. Ohms. Capacity. Frequency. Temperature

Documents & Downloads

User & Safety Instructions

User & Safety Instructions 2454499 Extech EX310 Handheld multimeter Calibrated to (ISO standards) Digital CAT III 600 V Display (counts): 2000

Description

The EX310 is a compact multimeter in robust soft rubber housing with contactless voltage test (NCV). Cables and wires can be tested for voltage. Ideally suited for electricians and similar use.

This text is machine translated.

Features

  • Standard measuring range V. A. Ω. Diode. Continuity
  • Non-contact voltage measurement (NCV).

Scope of delivery

  • Test Leads
  • Battery
  • User manual
  • ISO calibration certificate

Hints

Please note the sample calibration certificate stored under "Downloads" for the scope of the calibration.